4.3.2. Peripheral
No.
Description
Default
(1)
Device name
MDBT50Q-ATMS
(2)
Base UUID
0x9E, 0xCA, 0xDC, 0x24, 0x0E, 0xE5, 0xA9, 0xE0,
0x93, 0xF3, 0xA3, 0xB5, 0x00, 0x00, 0x40, 0x6E
(3)
Service UUID
0x0001
TX characteristic: 0x0003; RX characteristic: 0x0002
(4)
PHY mode
1Mbps
(5)
RF TX power
+8dBm
(6)
Connection interval mode
Mode 0(min. 20ms / Max. 40ms)
(7)
Baud rate
9600bps,n,8,1
(8)
Status of DC-to-DC converter
Disable (LDO mode)
(9)
32.768KHz oscillator
Using internal RC oscillator with 1000ms calibration time
(10)
Advertising time
Forever advertising with no timeout
(11)
Advertising Interval
0x0040
Advertising interval is 40 ms
(12)
Advertising LED pattern
0.5sec on / 0.5sec off
(13)
Connecting LED pattern
0.2sec on / 1.8secs off
(14)
Status of flow control
Disable
(15)
Logic of wake-up pin
Set logic low to wake up in deep sleep
(16)
Logic of BT connecting indicator
Output set as logic low when BT is connecting
(17)
Serial number
Display “ no data! ” string
(18)
ADC value
Value varies from input voltage between
0x0000 ~ 0x03FF (Hex).
(19)
State of response
Enabled
(20)
Firmware version
1.0