2.  WATER CHEMISTRY

(Corrosive water causes damage that will not be covered under warranty.)

For your health and the protection of your pool equipment, it is essential that your water be chemically balanced. 

The following levels must be used as a guide for balanced water.

Recommended Level(s)

Fiberglass Pools

Fiberglass Spas

Other Pool & Spa Types

Water Temp. °F (°C)

68 to 88 (20-31)

89 to 104 (32-40)

68 to 104 (20-40)

pH

7.3 to 7.4

7.3 to 7.4

7.6 to 7.8

Total Alkalinity (PPM)

120 to 150

120 to 150

80 to 120

Calcium Hardness (PPM)

200 to 300

150 to 200

200 to 400

Salt (PPM)

RP 316L SS

1000 MAXIMUM

1000 MAXIMUM

1000 MAXIMUM

Titanium

6000 MAXIMUM**

6000 MAXIMUM**

6000 MAXIMUM**

Free Chlorine (PPM)*

2 to 3

2 to 3

2 to 3

Total Dissolved 

Solids (PPM)

RP 316L SS

1000 MAXIMUM

1000 MAXIMUM

1000 MAXIMUM

Titanium

3000 MAXIMUM

3000 MAXIMUM

3000 MAXIMUM

Metals (PPM)

0

0

0

*Free Chlorine MUST NOT EXCEED 5 PPM!

•  Occasional chemical shock dosing of the pool or spa water should not damage the heater providing the water 

is balanced.

•  Automatic chemical dosing devices and salt chlorinators are usually more efficient in heated water. Unless 

controlled, they can lead to excessive chlorine levels, which can damage your heater.

•  Further advice should be obtained from your pool or spa builder, accredited pool shop, or chemical supplier 

for the correct levels for your water.

** 

Titanium is immune to saline and seawater.

Содержание RP-045

Страница 1: ...GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s ins...

Страница 2: ...2 Rev 5 reflects the following Table A Added Model Number column Changed row heading from CR24 to Ti Table C Added information rows for RP 185 RP 305 RP 495...

Страница 3: ...3 TABLE OF CONTENTS 1 WARNINGS 4 Pay Attention to These Terms 4 Caution 4 2 WATER CHEMISTRY 5 3 INSTALLATION GUIDELINES 7 Plumbing 7 Flow 7 Controls 8 Chemical feeders or salt water generators 8...

Страница 4: ...t and related system components Installation and service personnel are required by some states to be licensed Persons not qualified shall not attempt to install service or maintain this equipment Elev...

Страница 5: ...0 MAXIMUM 1000 MAXIMUM Titanium 6000 MAXIMUM 6000 MAXIMUM 6000 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM RP 316L SS 1000 MAXIMUM 1000 MAXIMUM 1000 MAXIMUM Titanium 3000...

Страница 6: ...175 3 1 4 83 1 1 2 38 3 4 19 13 1 2 343 3 1 8 79 2 64 0 25 013478 RP 125 125 000 36 634 4 3 16 106 8 7 8 225 3 1 4 83 1 1 2 38 3 4 19 15 3 8 391 3 1 8 79 3 64 0 34 013479 RP 185 185 000 54 218 5 1 8 1...

Страница 7: ...7 15 4 6 23 7 2 Designed and fabricated to the ASME B31 3 Process Piping Code 3 INSTALLATION GUIDELINES Plumbing Connections to the Indirect Pool Heater must be made with materials that have similar g...

Страница 8: ...direct adequate flow through the heat exchanger and must be augmented by using the manual valve to throttle flow to provide approximately 6 to 15 ft of head across the 995 exchanger Controls The Indir...

Страница 9: ...Limited Warranty is the date of original installation if properly documented if you are not able to provide documentary proof of the date of original installation the Effective Date will be the date...

Страница 10: ...d in any way by ANY persons or agencies other than those authorized by Raypak Raypak reserves the right at all times to inspect or require the return of the defective product or component part and to...

Страница 11: ...ISO 9001 REGISTERED QUALITY MANAGEMENT SYSTEM www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...

Отзывы: