Water Chemistry

(Corrosive water voids all warranties)

For your health and the protection of your pool equipment, it is essential that your water be chemically
balanced. The following levels must be used as a guide for balanced water.

Recommended Level(s) Fiberglass Pools Fiberglass Spas

Other Pool & Spa Types

Water Temp. (Deg. F)

68 to 88

89 to 104

68 to 104

pH

7.3 to 7.4

7.3 to 7.4

7.6 to 7.8

Total Alkalinity (PPM)

120 to 150

120 to 150

80 to 120

Calcium Hardness (PPM)

200 to 300

150 to 200

200 to 400

Salt (PPM)

RP 316L SS

1000 MAXIMUM

1000 MAXIMUM

1000 MAXIMUM

CR Super

Alloy

6000 MAXIMUM**

6000 MAXIMUM**

6000 MAXIMUM**

Free Chlorine (PPM)*

2 to 3

2 to 3

2 to 3

Total

Dissolved

Solids (PPM)

RP 316L SS

1000 MAXIMUM

1000 MAXIMUM

1000 MAXIMUM

CR Super

Alloy

3000 MAXIMUM

3000 MAXIMUM

3000 MAXIMUM

Metals (PPM)

0

0

0

*Free Chlorine MUST NOT EXCEED 5 PPM!

Occasional chemical shock dosing of the pool or spa water should not damage the heater providing

the water is balanced.

• Automatic chemical dosing devices and salt chlorinators are usually more efficient in heated water.

Unless controlled, they can lead to excessive chlorine level which can damage your heater.

• Further advice should be obtained from your pool or spa builder, accredited pool shop, or chemical

supplier for the correct levels for your water.

2

**

CR Superalloy can tolerate higher salt levels, and is even seawater resistant, but salt levels above 6000

PPM may cause damage to other components of the pool system, pool equipment or hardware.

Содержание RP-045

Страница 1: ...of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required...

Страница 2: ...3 2 to 3 Total Dissolved Solids PPM RP 316L SS 1000 MAXIMUM 1000 MAXIMUM 1000 MAXIMUM CR Super Alloy 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Metals PPM 0 0 0 Free Chlorine MUST NOT EXCEED 5 PPM Occasio...

Страница 3: ...cy resulting in the birth of a brain damaged or deformed child Pregnant women should stick to the 100 F 38 C maximum rule CAUTION 4 Before entering the spa or hot tub users should check the water temp...

Страница 4: ...nvironments Due to its unsurpassed corrosion resistance this unique super alloy option is a true salt water product now available from Raypak for the most demanding of applica tions from high chlorina...

Страница 5: ...Connections to the heat source plumbing should be made with 300 series stainless steel nipples Dielectric unions are recommended if dissimilar plumbing is used Connections to the pool system should be...

Страница 6: ...ugh resistance to direct adequate flow through the heat exchanger and must be aug mented by using the manual valve to throttle flow to provide approximately 6 to 15 ft of head across the 995 exchanger...

Страница 7: ...is Limited Warranty is the date of original installation if properly documented if you are not able to provide documentary proof of the date of original installation the Effective Date will be the dat...

Страница 8: ...in any way by ANY persons or agencies other than those authorized by Raypak Raypak reserves the right at all times to inspect or require the return of the defective product or component part and to v...

Отзывы: