26
After Start-Up
Pilot System Checkout Procedure
1. Turn on power to the ignition systems and turn gas
supply off.
2. Check ignition module as follows:
a. Set the poolstat above pool water temperature
to turn heater on.
b. Watch for continuous spark at the pilot burner.
c. Time the spark operation. Time must be within
the lockout timing period (15 or 90 seconds).
d. Turn poolstat down to turn off heater and wait
60 seconds on lockout models before begin-
ning step 3.
3. Turn on gas supply.
4. Set poolstat above pool water temperature to turn
on heater.
5. Systems should start as follows:
a. Spark will turn on and pilot gas valve will open
at once. Pilot burner should ignite after gas
reaches the pilot burner.
b. Spark ignition should cut off when pilot flame
is established.
c. Main gas valve should open and main burner
should ignite after gas reaches the burner
port.
INSPECTION
PROCEDURES
Burners
Clean main burners and air louvers of dust, lint and
debris. Keep heater area clear and free from combus-
tibles and flammable liquids. Do not obstruct the flow
of combustion and ventilating air. Make visual check of
burner and pilot flame. Yellow flame indicates
clogging of air openings. Lifting or blowing flame indi-
cates high gas pressure. Low flame indicates low gas
pressure.
Feel inlet and outlet pipes. Outlet should be only slight-
ly warmer than inlet. It should not be hot.
CONTROLS
Check all controls to see that they are operational. To
check electric safety turn off main burner. Observe
pilot burner when shutting off pilot gas. Ignition spark
should go on. Main gas valve will also drop out.
Fig. 32: Main Burner Flame
Fig. 33: Pilot Burner Flame
WARNING:
Should overheating occur or the gas
supply fails to shut off, turn off the manual gas
control to the appliance.
Содержание P-1083
Страница 20: ...20 Wiring Diagram Models 926 1223 with UG ...
Страница 21: ...21 Wiring Diagram Models 926 1826 with H Bypass ...
Страница 22: ...22 Wiring Diagram Models 2100 2500 ...
Страница 23: ...23 Wiring Diagram Models 3001 4001 ...
Страница 35: ...35 ...
Страница 36: ...36 www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ...