Raypak Hot Water Supply LAUNDRY-PAK Скачать руководство пользователя страница 2

  

 Boiler

   Model
  Number

       514
       624
       724
       824
       926
     1083
     1178
     1287
     1414
     1571
     1758
(2)   926

(2) 1083
(2) 1178

(2) 1287
(2) 1414

(2) 1571

(2) 1758

    

 Temperature Rise

80°F

90°F

100°F

      Gallons per Hour

  636

  565

  508

  779

  692

  623

  902

  802

  722

1025

  911

  820

1195

1062

  956

1397

1242

1118

1519

1350

1215

1661

1476

1328

1823

1620

1458

2025

1800

1620

2268

2016

1815

2609

2319

2087

3105

2760

2484

3727

3313

2982

4348

3865

3479

4970

4418

3976

 

 Boiler

  Model
Number

    514
    624
    724
    824
    962
  1125
  1223
  1336
  1468
  1631
  1826

  2100

  2500

  3001

  3500

  4001

    

Temperature Rise

80°F      90°F     100°F
      Gallons per Hour

  636      565        508
  779      692        623
  902      802        722
1025      911        820
1150    1023        920
1346    1196      1076
1464    1301      1171
1599    1421      1279
1756    1560      1404
1951    1734      1560
2184    1941      1747
2300    2046      1840

2692    2392      2152
2928    2602      2342

3198    2842      2558
3512    3120      2808

3902    3468      3120

4368    3882      3494

  235

30 x 80

  335

36 x 80

  390

42 x 72

  534

42 x 92

  684

54 x 78

  803

54 x 90

  922

54 x 102

1164

60 x 105

Feet

HP

Head

0.25

  7.0
  7.2
  9.3

0.33

11.7
10.5

0.75

16.0
16.2
17.5

0.75

18.0
19.0
19.7

0.33

10.5

1.00

16.6

0.75

16.0

0.75

16.2

2.00

23.6

0.75

17.5
18.0

2.00

24.8

0.75

19.0

2.00

25.5

0.75

19.7

2.00

26.6

Number         Gal

Total GPH

Washers      /Cycle

  /Cycle

_______  x  _______  = _______
_______  x  _______  = _______
_______  x  _______  = _______
_______  x  _______  = _______
_______  x  _______  = _______

       Total GPH  ________

Multiply by # cycle/hour x _______
TOTAL DEMAND GPH  _______

Selection:
Boiler: W1 - _______
Tank:  _______ gallons

Sizing:

1. Calculate the hot water demand:

Number of machines x gallons per
load  x number of cycles per hour
= GPH required.

2. Enter chart at Temperature

Rise find the GPH  closest to,
but not less than, GPH
calculated.

3. Select the water heater, tank and

circulator  recommended.

For complete and detailed piping diagram see Drawing 8054

Normal

Capacity

Gallons

Diameter

X

Length

Type 

WH Indoor

 Water Heater

Type 

WH Outdoor 

Water Heater

Tank

Pump*

*Based on 5-15grains  per gallon hardness.  Feet Head is based on equivalent length of pipe, valve and fittings between water heater and
tank placed five (5) feet apart. 

 Raypak, Inc. reserves the right to make product changes or improvements at any time without notice.

©RAYPAK, INC., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725

Litho USA

Sample piping diagram showing one water heater and one tank.

For two water heaters and one tank see Drawing 8069.