8
4. Remove retainer clip at bulb and remove capillary
bulb.
5. Remove aquastat, using extreme care to see that
the capillary tube is not kinked or broken. (Never
use anything but fingers to bend capillary tubing).
Removing the High Limit
1. Turn off electrical power to heater at main discon-
nect.
2. Disconnect wires from high limit.
3. Remove screws holding high limit to tank.
Removing the Pressure Switch
1. Turn off electrical power to heater at main discon-
nect.
2. Drain heater.
3. Disconnect pressure switch leads.
4. Unscrew pressure switch.
Removing the Magnetic
Contactor
1. Turn off electric power to heater at main discon-
nect.
2. Remove wires from contactor.
3. Remove screw holding contactor to cabinet.
Winterizing
Damage will occur if water is allowed to freeze inside
the heater. Normally the heater will drain when the spa
is drained. If the heater is positioned lower than the
spa a drain valve must be added at the heater inlet.
The water must be drained from the heater and the
main disconnect switch shut off.
Filter
CAUTION:
Do not allow filter to become clogged to
the extent that cycling of the pressure switch occurs.
This can result in accelerated wear of the magnetic
contactor. Contactor damage caused by dirty filter is
not covered by warranty.