4. Remove retainer clip at bulb and remove capillary

bulb.

5. Remove aquastat, using extreme care to see that

the capillary tube is not kinked or broken. (Never

use anything but fingers to bend capillary tubing).

Removing the High Limit

1. Turn off electrical power to heater at main discon-

nect.

2. Disconnect wires from high limit.

3. Remove screws holding high limit to tank.

Removing the Pressure Switch

1. Turn off electrical power to heater at main discon-

nect.

2. Drain heater.

3. Disconnect pressure switch leads.

4. Unscrew pressure switch.

Removing the Magnetic

Contactor

1. Turn off electric power to heater at main discon-

nect.

2. Remove wires from contactor.

3. Remove screw holding contactor to cabinet.

Winterizing

Damage will occur if water is allowed to freeze inside

the heater. Normally the heater will drain when the spa

is drained. If the heater is positioned lower than the

spa a drain valve must be added at the heater inlet.

The water must be drained from the heater and the

main disconnect switch shut off.

Filter

CAUTION:

Do not allow filter to become clogged to

the extent that cycling of the pressure switch occurs.

This can result in accelerated wear of the magnetic

contactor. Contactor damage caused by dirty filter is

not covered by warranty.

Содержание els 552-2

Страница 1: ...11 11 08 P N 240362 Rev 22 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance To do so may...

Страница 2: ...0 Salt ppm 6000 Maximum 6000 Maximum 6000 Maximum Free Chlorine ppm 2 3 2 3 2 3 Total Dissolved Solids ppm 3000 Maximum 3000 Maximum 3000 Maximum Free Chlorine MUST NOT EXCEED 5 ppm Occasional chemica...

Страница 3: ...g the holes provided The heater must be located where leakage of heat exchanger or connections will not damage the area adjacent to the heater or structure Water Connections The Spa Pak has 1 1 2 male...

Страница 4: ...of the units Field Wiring Heater requires three wire service With 240 VAC there are two hot wires and a grounding conductor Even when metallic conduit is used the grounding conductor must be run to th...

Страница 5: ...ize Wire Size including ground Size of Fused Disconnect amps ELS 1102 2 46 1 6 60 ELS 552 2 23 1 2 10 30 Use a reducer bushing Table A Wire Sizes for Field Connection L1 L2 MODEL ELS 552 2 ONLY SCHEMA...

Страница 6: ...sumer Product Safety Commission rec ommends the following guidelines When using this electrical equipment basic safety precautions should always be followed including the following 1 READ AND FOLLOW A...

Страница 7: ...d also damaging the heater If the pH drops below 7 2 the heater will be severely damaged This will result in cor rosion of the heat exchanger Heat exchanger damage resulting from chemical imbalance is...

Страница 8: ...re switch Removing the Magnetic Contactor 1 Turn off electric power to heater at main discon nect 2 Remove wires from contactor 3 Remove screw holding contactor to cabinet Winterizing Damage will occu...

Страница 9: ...ather Use spa cover Call electrician Check resistance element bundle 240V 11 kw 5 0 to 5 8 OHMS 240V 5 5 kw 10 0 to 11 6 OHMS Spa does not reach temperature Mis adjusted knob stop Low flow Re adjust k...

Страница 10: ...0 F 1 1 8 1 0 0 t i m i L h g i H 7 8 Contactor Wire Kit 001813F 001813F 9 Thermostat Control 003346F 003346F 1 6 7 0 5 6 1 6 7 0 5 6 h c t i w S e l g g o T 0 1 F 2 1 8 1 0 0 F 2 1 8 1 0 0 t h g i L...

Страница 11: ...11...

Страница 12: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...

Отзывы: