4. Remove retainer clip at bulb and remove capillary

bulb.

5. Remove aquastat, using extreme care to see that

the capillary tube is not kinked or broken. (Never

use anything but fingers to bend capillary tubing).

Removing the High Limit

1. Turn off electrical power to heater at main discon-

nect.

2. Disconnect wires from high limit.

3. Remove screws holding high limit to tank.

Removing the Pressure Switch

1. Turn off electrical power to heater at main discon-

nect.

2. Drain heater.

3. Disconnect pressure switch leads.

4. Unscrew pressure switch.

Removing the Magnetic

Contactor

1. Turn off electric power to heater at main discon-

nect.

2. Remove wires from contactor.

3. Remove screw holding contactor to cabinet.

Winterizing

Damage will occur if water is allowed to freeze inside

the heater. Normally the heater will drain when the spa

is drained. If the heater is positioned lower than the

spa a drain valve must be added at the heater inlet.

The water must be drained from the heater and the

main disconnect switch shut off.

Filter

CAUTION:

Do not allow filter to become clogged to

the extent that cycling of the pressure switch occurs.

This can result in accelerated wear of the magnetic

contactor. Contactor damage caused by dirty filter is

not covered by warranty.

Содержание ELS 1102-2

Страница 1: ... 11 11 08 P N 240362 Rev 22 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance To do so may result in an explosion or fire Models ELS 552 2 ELS 1102 2 Electric SPA PAK Heater ...

Страница 2: ...00 Salt ppm 6000 Maximum 6000 Maximum 6000 Maximum Free Chlorine ppm 2 3 2 3 2 3 Total Dissolved Solids ppm 3000 Maximum 3000 Maximum 3000 Maximum Free Chlorine MUST NOT EXCEED 5 ppm Occasional chemical shock dosing of the pool or spa should not damage the heater providing the water is balanced Automatic chemical dosing devices and salt chlorina tors are usually more efficient in heater water unle...

Страница 3: ...ng the holes provided The heater must be located where leakage of heat exchanger or connections will not damage the area adjacent to the heater or structure Water Connections The Spa Pak has 1 1 2 male NPT inlet and outlet connections at the right side of the heater The inlet is at the base of the heater and must be piped directly to the filter discharge to ensure proper flow direction Minimum flo...

Страница 4: ... of the units Field Wiring Heater requires three wire service With 240 VAC there are two hot wires and a grounding conductor Even when metallic conduit is used the grounding conductor must be run to the supply ground Field wiring connections are made to the electrical entry at the left side of the unit A hole in the jacket is provided for a 1 trade size conduit hub The location of the field wiring...

Страница 5: ...Size Wire Size including ground Size of Fused Disconnect amps ELS 1102 2 46 1 6 60 ELS 552 2 23 1 2 10 30 Use a reducer bushing Table A Wire Sizes for Field Connection L1 L2 MODEL ELS 552 2 ONLY SCHEMATIC DIAGRAM LADDER DIAGRAM ...

Страница 6: ...nsumer Product Safety Commission rec ommends the following guidelines When using this electrical equipment basic safety precautions should always be followed including the following 1 READ AND FOLLOW ALL INSTRUCTIONS 2 To reduce the risk of injury a The water in a pool or tub should never exceed 104 F 40 C A water temperature in excess of 104 F is considered unsafe for all persons Lower water temp...

Страница 7: ...nd also damaging the heater If the pH drops below 7 2 the heater will be severely damaged This will result in cor rosion of the heat exchanger Heat exchanger damage resulting from chemical imbalance is not covered by the warranty Element Inspection and Replacement The element assembly head is removed as follows 1 Turn off electrical power to heater at the main dis connect and turn off water supply...

Страница 8: ...ure switch Removing the Magnetic Contactor 1 Turn off electric power to heater at main discon nect 2 Remove wires from contactor 3 Remove screw holding contactor to cabinet Winterizing Damage will occur if water is allowed to freeze inside the heater Normally the heater will drain when the spa is drained If the heater is positioned lower than the spa a drain valve must be added at the heater inlet...

Страница 9: ...eather Use spa cover Call electrician Check resistance element bundle 240V 11 kw 5 0 to 5 8 OHMS 240V 5 5 kw 10 0 to 11 6 OHMS Spa does not reach temperature Mis adjusted knob stop Low flow Re adjust knob stop Check filter skimmer basket pump Heating element continuously burning out High input voltage Poor water chemistry Heating element split open Call electric company See Water Chemistry on page...

Страница 10: ...0 0 F 1 1 8 1 0 0 t i m i L h g i H 7 8 Contactor Wire Kit 001813F 001813F 9 Thermostat Control 003346F 003346F 1 6 7 0 5 6 1 6 7 0 5 6 h c t i w S e l g g o T 0 1 F 2 1 8 1 0 0 F 2 1 8 1 0 0 t h g i L r o t a c i d n I 1 1 F 5 8 8 6 0 0 F 5 8 8 6 0 0 b o n K 2 1 F 6 8 8 6 0 0 F 6 8 8 6 0 0 p o t s b o n K 3 1 5 1 6 0 0 9 5 1 6 0 0 9 e t a l P l a i D 4 1 15 Wire Kit Complete N A N A A N A N p o T...

Страница 11: ...11 ...

Страница 12: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ...

Отзывы: