Raypak Commercial Space Heating and Domestic Water Скачать руководство пользователя страница 3

R

ELIABILITY

A

DVANCED 

B

URNER 

T

ECHNOLOGY

The heart of any boiler is the burner. It’s a critical
component that’s got to be designed right. That’s
why Raypak spent over four years perfecting the
ADB burner. The result is an industrial grade, fan-
assisted burner that provides superior perfor-
mance and is practically indestructible.

Standard high efficiency boilers use burners that
are either  flimsy flame retention screens that burn
out, or radial perforated burners that eventually
clog and operate at reduced efficiencies. Unlike
these burner designs, the patented advanced
design burner 

will not clog or burn out

. In fact,

Raypak is so confident, the new burner head is
backed with a T

EN

Y

EAR

U

NCONDITIONAL

W

ARRANTY

.

The ADB’s burner utilizes a solid metal  bluff-body
burner head to generate a high-intensity aerody-
namically stabilized flame. The burner’s   turbulent
mixing action reduces residence time  and increas-
es flue gas recirculation. The result is clean, effi-
cient combustion with NOx emissions well within
the limits of the most restrictive air quality require-
ments.*

This is one tough burner and the warranty proves it.

* NOx emissions: 
0-30 ppm depending on combustion air quality and
gas composition.

ERROR

HEAT

C

ENTRAL 

P

OINT 

W

IRING

A

ND 

D

IAGNOSTICS

Raypak boilers have a well earned reputation for
being easy to service. The ADB is no exception. In
fact, the ADB sets a whole new standard for ser-
viceability – because it’s the first commercial boiler
to incorporate central point wiring (CPW).

Unlike older control technologies, CPW individually
monitors each and every boiler control and safety
function. Using an intuitive LED display referred to
as the Operation Status Center, CPW gives split-
second feedback on boiler firing status. Should
service be required, the ADB will even indicate
which component requires attention by illuminat-
ing the appropriate fault LED located on the ADB’s
U-2 Diagnostics Panel. 

Содержание Commercial Space Heating and Domestic Water

Страница 1: ... Space Heating and Domestic Water ADB Advanced Design Boiler Up to 97 Thermal Efficiency Ultra low NOx Small Footprint Aerodynamically Stabilized Burner Full Diagnostics Multiple Venting Options Reduced Vent Sizes N e w 1 5 0 0 M B T U TM ...

Страница 2: ...to corrosion THIRD GENERATION TECHNOLOGY After two decades of trial and error the boiler industry has finally realized that high efficiency and long product life can only be obtained by preventing condensation from occurring in the combustion chamber Raypak s Advanced Design Boiler is the first of a new generation of boilers that can obtain ultra high efficiencies without compromising product life...

Страница 3: ...urbulent mixing action reduces residence time and increas es flue gas recirculation The result is clean effi cient combustion with NOx emissions well within the limits of the most restrictive air quality require ments This is one tough burner and the warranty proves it NOx emissions 0 30 ppm depending on combustion air quality and gas composition ERROR HEAT CENTRAL POINT WIRING AND DIAGNOSTICS Ray...

Страница 4: ...rrosion proof coatings for extra protection The headers are bronze the heat exchanger tubes are made of cupro nickel and are coated with a condensate impervious epoxy enamel All non stainless internal fittings are either epoxy coated or are chemically immune The tube bundle casing is fabricated from AL29 4C stainless steel and the outer jacket has an electrostatically applied powder coat finish th...

Страница 5: ...rrode or erode and can handle aggressive and hard water with ease SMALL FOOTPRINT The ADB occupies less than 51 2 sq ft of floor space VENT PRESSURE SWITCHES Enhance safety by verifying proper burner operation UP FRONT CONTROLS Easy access to all controls and gas train components ADVANCED BLUFF BODY BURNER Industrial tough solid metal burner head won t clog or burn out and it s backed with a TEN Y...

Страница 6: ...ssure Regulator Safety Shut Off Valve Redundant Firing Mode On Off Factory Fire Tested CSD 1 Compliant Gas Train CONTROLS 120V 60Hz 1ø Power Supply 120 24V Transformer 100 Pilot Safety Electronic Intermittent Ignition IID High Limit Safeties Central Point Wiring Full Boiler Diagnostics Fan Proving Switch Flow Switch Blocked Flue Switch CONSTRUCTION Front Controls Enclosed Polytuf Powder Coat Finis...