Raypak Commercial Space Heating and Domestic Water Скачать руководство пользователя страница 1

A N

EW

E

RA

I

N

B

OILER 

D

ESIGN

Commercial Space Heating
and Domestic Water

ADB   

Advanced Design Boiler

Up to 97%
Thermal Efficiency

Ultra low NOx

Small Footprint

Aerodynamically 
Stabilized Burner

Full Diagnostics

Multiple Venting 
Options

Reduced Vent 
Sizes

New!

1500 

MBTU

TM

Содержание Commercial Space Heating and Domestic Water

Страница 1: ... Space Heating and Domestic Water ADB Advanced Design Boiler Up to 97 Thermal Efficiency Ultra low NOx Small Footprint Aerodynamically Stabilized Burner Full Diagnostics Multiple Venting Options Reduced Vent Sizes N e w 1 5 0 0 M B T U TM ...

Страница 2: ...to corrosion THIRD GENERATION TECHNOLOGY After two decades of trial and error the boiler industry has finally realized that high efficiency and long product life can only be obtained by preventing condensation from occurring in the combustion chamber Raypak s Advanced Design Boiler is the first of a new generation of boilers that can obtain ultra high efficiencies without compromising product life...

Страница 3: ...urbulent mixing action reduces residence time and increas es flue gas recirculation The result is clean effi cient combustion with NOx emissions well within the limits of the most restrictive air quality require ments This is one tough burner and the warranty proves it NOx emissions 0 30 ppm depending on combustion air quality and gas composition ERROR HEAT CENTRAL POINT WIRING AND DIAGNOSTICS Ray...

Страница 4: ...rrosion proof coatings for extra protection The headers are bronze the heat exchanger tubes are made of cupro nickel and are coated with a condensate impervious epoxy enamel All non stainless internal fittings are either epoxy coated or are chemically immune The tube bundle casing is fabricated from AL29 4C stainless steel and the outer jacket has an electrostatically applied powder coat finish th...

Страница 5: ...rrode or erode and can handle aggressive and hard water with ease SMALL FOOTPRINT The ADB occupies less than 51 2 sq ft of floor space VENT PRESSURE SWITCHES Enhance safety by verifying proper burner operation UP FRONT CONTROLS Easy access to all controls and gas train components ADVANCED BLUFF BODY BURNER Industrial tough solid metal burner head won t clog or burn out and it s backed with a TEN Y...

Страница 6: ...ssure Regulator Safety Shut Off Valve Redundant Firing Mode On Off Factory Fire Tested CSD 1 Compliant Gas Train CONTROLS 120V 60Hz 1ø Power Supply 120 24V Transformer 100 Pilot Safety Electronic Intermittent Ignition IID High Limit Safeties Central Point Wiring Full Boiler Diagnostics Fan Proving Switch Flow Switch Blocked Flue Switch CONSTRUCTION Front Controls Enclosed Polytuf Powder Coat Finis...