Control Panel
Mounting Screws (4)
Fig. #RP 8267
CONTROLS/ADJUSTMENTS/REPLACEMENTS
Temperature
Adjust Buttons
Mode Button
LCD Display
Fig. #2000
MILLIVOLT CONTROLS
The pool or spa water temperature is controlled by
the pool heater thermostat on the upper front panel of
the heater. The control center contains an On/Off
switch and one or two thermostats.
Thermostats are fitted with a means of limiting the
upper temperature limit below the maximum level. The
knob stop adjustment ring illustrated below is adjustable
by loosening the set screw, rotating the knobstop ring to
the desired location and retightening the set screw.
SPA TEMPERATURE RANGE POOL TEMPERATURE RANGE
STAND-BY
TEMPRATURE
SET SCREW
KNOB STOP RING
Fig. #8103.2
KNOB STOP SHOWN ABOVE IS
IN THE SPA TEMPERATURE RANGE
24
Bypass
Hi Limit
(Located
in Return
Header)
AGS Hi-
Limit
(Located
in Inlet/
Oulet
Header)
Unitherm
Governor
Drain Plug
Fig #2005
SECTION 4 / SERVICING INSTRUCTIONS
GENERAL LOCATION OF CONTROLS
Drain Plug
(Located in
Return
Header)
Ignition
Control (IID)
Digital
Thermostat
Module
Roll-Out
Switch
Gas Valve
Pilot
CONTROL PANEL REMOVAL
1. Remove (4) screws from sides of control panel.
2. Rotate control panel down until panel stops. Do
not force.
NOTE:
Caution must be taken not to damage controls
or wiring.
On-Off Switch
Transformer
Содержание C-R185A to P-R405A
Страница 19: ...Fig 4 Fig 5 Fig 3 JACO FITTING BULB CLIP RE INSTALLED IN OUT HEADER ON OPPOSITE SIDE 19 ...
Страница 22: ...WIRING DIAGRAM IID UNITS atmospheric 22 ...
Страница 23: ...WIRING DIAGRAM IID UNITS Low NOx 23 ...
Страница 35: ...35 ...
Страница 37: ...37 ...
Страница 39: ...39 ...
Страница 40: ...40 ...
Страница 41: ...41 ...