26
Item
Range
Default
Value
Access Level
Description
Pump Off Time 3
12:00A–11:59P
---
Installer
Select OFF time for Pump Period #3
to stop.
Pump Speed 3
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the
selected pump output (which connects
to the pump for the selected speed)
for this pump period. On Variable
speed pumps, this denotes the PWM
signal to be provided to the pump for
pump operation.
Return Valve 3
Pool/Spa
Pool
Installer
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 3
Pool/Spa
Pool
Installer
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Pump On Time 4
12:00A–11:59P
---
Installer
Select ON time for Pump Period #4 to
take effect.
Pump Off Time 4
12:00A–11:59P
---
Installer
Select OFF time for Pump Period #4
to stop.
Pump Speed 4
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the
selected pump output (which connects
to the pump for the selected speed)
for this pump period. On Variable
speed pumps, this denotes the PWM
signal to be provided to the pump for
pump operation.
Return Valve 4
Pool/Spa
Pool
Installer
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 4
Pool/Spa
Pool
Installer
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Faults Last
Installer/
Service
Fault history starting with the most
recent and going back to 10 last faults.
Using the UP/DOWN buttons scrolls
through the fault history. If there are
no faults present, the display will read
“All Faults Clear”.
Clear Faults
Installer/
Service
Holding down the UP and DOWN
buttons for 3+ seconds clears the
recorded fault history and “Faults
Cleared” appears on the display.
Run Hours
XXXX
Cycles
XXXX
Installer/
Service
Displays the number of run hours that
the compressor has been running as
well as the number of cycles that the