R.ESPINAR S.L.

                                                

                                                                  

AEi/01

 

 

7/22

 Code 

Ref.  Description 

 90130775 

CCI-75  Non-perforated stainless steel basket AISI-316 of Ø380x260mm 

for AES-75 and AES-110. (2 per autoclave AES-75 and 3 per 

AES-110) 

 90130850  CCI-150  Non-perforated stainless steel basket AISI-316 of Ø475x360mm  

for AES-150. (2 per autoclave) 

 90130740  CEP-7040 Pippete sterilize cylinder of Ø70x400mm 

 90131340  CEP-1340 Pippete sterilize cylinder of Ø130x400mm 

  90131326  CEP-1326  Petri capsules sterilize cylinder of Ø130x260mm 

  90131347  CEP-1347  Petri capsules sterilize cylinder of Ø130x400mm 

   90131428       SRA-1      Height adjustable support with shelves for AE/AES-28 

   90131475       SRA-2      Height adjustable support with shelves for AE/AES-75 

   90131510       SRA-3      Height adjustable support with shelves for AE/AES-110 

   90131550       SRA-4      Height adjustable support with shelves for AE/AES-150 

 

All accessories must be installed in factory 

 

  

INSTALLATION

 

 

Install the apparatus on a stable and solid surface. 

 

Don’t install the autoclave in areas where there is danger  of fire or explosion. 

 

Don’t block or cover the rear ventilation grid. 

 

Connect a flexible tube to the rear outlet (11) for drainage. 

 

CONNECTION TO THE MAINS

 

There is the characteristics plate situated at the rear, indicating the voltage and power. 

Check to make sure that your electrical installations have the same conditions. 

The plug of the oven is a SCHUKO with central and lateral connection, for security 

reasons the oven must be installed to ground. 

The triphasic autoclaves (AE-110 DRY and AE-150 DRY) have a normalized plug of 16A, 

3 poles, neutral and ground. 

The autoclaves are equipped from the factory to be connected at 380V+N and ground, but 

they can be changed into triphasic 220V and ground following the instructions given in 

CHANGE OF VOLTAGE. 

CHANGING VOLTAGE

 

Содержание AE-110 DRY

Страница 1: ...INAR S L AEi 01 1 22 R ESPINAR S L INSTRUCTION MANUAL FOR USE AND MAINTENANCE AUTOCLAVES FOR STERILIZATION MICROPROCESSOR CONTROLLED WITH DRY AND PREVACUUM Models AE 28 DRY AE 75 DRY AE 110 DRY AE 150...

Страница 2: ...r functions page 4 Technical specifications page 5 Characteristics page 6 Accessories page 6 Installation page 7 Connection to the mains page 7 Changing voltage page 8 Programming mode page 9 Alphanum...

Страница 3: ...itch 4 Mano vacuometre 5 Thermal printer of continuous sheet 6 Thermal protector of the cover 7 Filling of the condensed water tank REAR VIEW 8 Ventilation bacteriological filter 9 Safety valve 10 Con...

Страница 4: ...RE This switch is used during a sterilization program edition to select and edit the figures 8 Switch for sterilization time selection CLOCK This switch is used during the edition of a sterilization p...

Страница 5: ...during 2 seconds If this operation is made in the final onform will appear the message STOP instead of the message STERILIZATION OK TECHNICAL SPECIFICATION Apparatus Steam sterilization autoclave Ste...

Страница 6: ...lexible wire of silicone to introduce it into the liquids or bags to sterilize at a real time and temperature not depending on the volume or capacity of the material to sterilize 90131300 IT Thermal p...

Страница 7: ...ble support with shelves for AE AES 150 All accessories must be installed in factory INSTALLATION Install the apparatus on a stable and solid surface Don t install the autoclave in areas where there i...

Страница 8: ...f the autoclave Change the metallic bridges on the binding post from the star connection to a delta connection as indicates below Take out the neutral blue from terminal space of main entrance and con...

Страница 9: ...Solids 12 P1 121 1 1 30 Solids 25 P2 133 2 1 20 Solids 30 P3 121 1 1 20 Liquids This programs cannot be modified in case of modification protect or unprotect more numbers of programs See the programs...

Страница 10: ...get into the program editor desired and it will be shown the letter P to indicate the edition situation Press the switch n 7 THERMOMETER to edit the sterilization data Pressing the switch n 8 CLOCK wi...

Страница 11: ...ve a minimum buffer of 150 characters 9 PINS CONNECTOR If a printer is connected see paragraph PRINTER MODE SOLID LIQUID MODE If the autoclave is not equipped with an accessory code number 90131400 re...

Страница 12: ...and a few seconds later will appear a number of a program it will always be the last program executed and the message LACK OF WATER FILLING OF THE CONDENSATION TANK Unscrew the cap of the water inlet...

Страница 13: ...initializing the process of sterilization The microprocessor screen will keep you informed of every step of the process The sterilization cycle of a solid without dry is composed by the following phas...

Страница 14: ...istilled water in the sterilization chamber HEATING Increase of pressure heating UNLOADING Automatic unload of the water and steam of the chamber to the condensed water tank only in solid program DRYI...

Страница 15: ...THE LID OPEN DURING THIS TIME If the cycle done before was of liquids in the screen will be possible to read WATER IN CHAMBER alternatively with START TO CONTINUE See ADVISE MESSAGES DO NOT OPEN THE A...

Страница 16: ...OW YES 4 Press the switch 11 PRO in the screen will appear PRINTING and it will give us an inform of the last sterilization without data as the following example DATA PRINTING RESULTS In automatic pri...

Страница 17: ...RINT NOW Press again switch n 11 PRO and it will appear in initial screen With this mode of printer every time the sterilization cycle is initialized the printer automatically will print data with a c...

Страница 18: ...CREASE to modify the n of program that is suitable do be block or unblock 0 No program protected 1 To 10 Program to protect from P0 to P9 3 To exit the screen and validate the n of programs protected...

Страница 19: ...an acoustic signal and the light of LCD Pressing the switch START STOP the sound stops When pressing the switch will disappear the failure warning message also and the lights of the LCD in case you do...

Страница 20: ...ure does not evolute correctly that means there must be a problem and the cycle is aborted FAULT TEMPERATURE During the sterilization process the temperature must be between a scale of value to guaran...

Страница 21: ...the apparatus indicated on the characteristic plate at the rear of the apparatus GUARANTEE This apparatus is guaranteed for a one year period against any fabrication failure or defective part The gua...

Страница 22: ...028 13380075 13400011 and 13420015 fulfil with the directives of security 73 23 CEE Low Tension and 89 336 CEE Electromagnetic compatibility According to International Regulations EN 61010 1 EN 61010...

Отзывы: