24
Adjustments
Introduction
Without a properly installed safety reversal system, persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage door.
•
Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal
system.
•
After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on
contact with 1-1/2" (3.8 cm) high object (or 2x4 laid flat) on floor.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
Your garage door opener is designed with electronic controls to make setup and adjustments easy. The
adjustments allow you to program where the door will stop in the open (UP) and close (DOWN) position. The
electronic controls sense the amount of force required to open and close the door. The force is adjusted
automatically when you program the travel. While programming the travel, the UP and DOWN buttons can be
used to move the door as needed. During the Automatic Force Setup, the door will automatically open and
close.
UP (Open)
DOWN (Close)
PROGRAMMING BUTTONS
The programming buttons are located on the side panel of the garage door opener and are used to program the
travel. While programming, the UP and DOWN buttons can be used to move the door as needed.
PROGRAMMING BUTTONS
UP
Button
Adjustment
Button
DOWN
Button