background image

Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door. 
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the

other control may also need adjustment.

• After ANY adjustments are made, the safety reversal

system MUST be tested. Door MUST reverse on
contact with 1-1/2" (3.8 cm) high object (or 2x4 laid
flat) on the floor.

25

ADJUSTMENT STEP 3

Test the Safety Reversal System

TEST

• With the door fully open, place a 1-1/2" (3.8 cm)

board (or a 2x4 laid flat) on the floor, centered
under the garage door.

• Operate the door in the down direction. The door

must

reverse on striking the obstruction.

ADJUST

• If the door stops on the obstruction, it is not

traveling far enough in the down direction.
Increase the DOWN limit by turning the DOWN
limit adjustment screw counterclockwise 1/4 turn.

NOTE:

On a sectional door, make sure limit

adjustments do not force the door arm beyond a
straight up and down position. See the illustration
on page 21.

• Repeat the test.

• When the door reverses on the 1-1/2" (3.8 cm)

board, remove the obstruction and run the opener
through 3 or 4 complete travel cycles to test
adjustment.

IMPORTANT SAFETY CHECK:

Test the Safety Reverse System after:

• Each adjustment of door arm length, limits, or

force controls.

• Any repair to or adjustment of the garage door

(including springs and hardware).

• Any repair to or buckling of the garage floor.

• Any repair to or adjustment of the opener.

ADJUSTMENT STEP 4

Test the Protector System

®

• Press the remote control push button to open the

door.

• Place the opener carton in the path of the door.

• Press the remote control push button to close the

door. The door will not move more than an inch
(2.5 cm), and the opener lights will flash.

The garage door opener will not close from a remote
if the indicator light in either sensor is off (alerting
you to the fact that the sensor is misaligned or
obstructed).

If the opener closes the door when the safety
reversing sensor is obstructed (and the sensors
are no more than 6" (15 cm) above the floor), call
for a trained door systems technician.

Safety Reversing Sensor

Safety Reversing Sensor

Without a properly installed safety reversing sensor,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door. 

1-1/2" (3.8 cm) board 
(or a 2x4 laid flat)

WARNING

CAUTION

WARNING

WARNING

WARNING

CAUTION

WARNING

WARNING

Содержание 2280RGD 1/2 HP

Страница 1: ...l Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and pro...

Страница 2: ...problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PIN 32 Repair Pa...

Страница 3: ...your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift t...

Страница 4: ...type and height of your garage door Survey your garage area to see if any of the conditions below apply to your installation Additional materials may be required You may find it helpful to refer back...

Страница 5: ...is packaged in two cartons which contain the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packing material Part...

Страница 6: ...ocket Align the two bolt holes in the rail with those in the motor unit bracket Insert two 1 4 20x5 8 hex bolts and lock nuts Tighten securely with a 7 16 socket wrench ASSEMBLY STEP 2 Install the Tro...

Страница 7: ...ted to garage door BEFORE installing opener to avoid entanglement 5 Install garage door opener 7 feet 2 13 m or more above floor 6 Mount emergency release handle 6 feet 1 83 m above floor 7 NEVER conn...

Страница 8: ...the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 12 for ceiling installation To prevent possible SERIOUS INJURY...

Страница 9: ...P CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEILING MOUNT ONLY Door Spring Header...

Страница 10: ...way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes an...

Страница 11: ...r Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional g...

Страница 12: ...track It should lie flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installat...

Страница 13: ...garage door you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires Use one rail channel for the door control wire and the other chan...

Страница 14: ...s convenient for setting an ideal door to rail distance Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 l...

Страница 15: ...ilize the two center mounting tabs you must triangulate the vertical brackets for additional stability Figure 3 6 Check to make sure the rail is centered over the door or in line with the header brack...

Страница 16: ...top of motor unit above the terminal block on the back panel Figure 4 5 Strip 7 16 11 mm of insulation from each set of wires Insert door control wire into quick connect terminals by color white wire...

Страница 17: ...the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Secure with an...

Страница 18: ...k Wire PERMANENT WIRING CONNECTION White Wire Black Wire WARNING CAUTION WARNING WARNING INSTALLATION STEP 11 Complete Safety Reversing Sensor Installation ALIGNING THE SAFETY SENSORS Plug in the open...

Страница 19: ...cket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insul...

Страница 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Страница 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Страница 22: ...ener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manually close the door...

Страница 23: ...ined in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close co...

Страница 24: ...the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum am...

Страница 25: ...e 1 1 2 3 8 cm board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each adjustment of d...

Страница 26: ...t when the Light feature on the Multi Function Door Control is activated Bulb size is 100 watts maximum SAFETY SIGNAL light feature Lights will also turn on when someone walks through the open garage...

Страница 27: ...to stop the door while it s opening Light feature Press the Light button to turn the opener light on or off It will not control the opener lights when the door is in motion If you turn it on and then...

Страница 28: ...or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operati...

Страница 29: ...Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door tr...

Страница 30: ...control touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminal...

Страница 31: ...d release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate...

Страница 32: ...the four buttons for the present PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then press Enter The motor unit lig...

Страница 33: ...sending eyes with 3 9 m 2 conductor bell wire attached 10 41A5266 1 Safety sensor bracket 11 41B4494 1 2 Conductor bell wire white white red 12 178B35 Curved door arm section NOT SHOWN 41A4675 7 Insta...

Страница 34: ...ket light socket limit switch 8 41A5388 Motor drive assy complete with 8a 144B41 22T Pulley 8b 144B42 28T Pulley 8c 20B17 Drive belt 8d 158A69 Retainer rings 8e 41C556 Isolator bracket spacers 8f 41A5...

Страница 35: ...This temporary password can be limited to a programmable number of hours or entries 59LM Outside Keylock Operates the garage door automatically from the outside when remote control is not handy 371RGD...

Страница 36: ...ipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be re...

Отзывы: