Specifications

Environment

Product

Ambient
Temperature

Relative
Humidity

Protection

Lyda lamp head

-10°C to 35°C
(14°F to 95°F)
storage maximum
is 45°C (113°F)

20-100%, condensing,
non-corrosive, sulfur
residue free

suitable for
damp locations

LED driver

-40°C to 55°C
(-40°F to 131°F)
storage maximum
is 85°C (185°F)

10-100%, condensing,
non-corrosive

suitable for
damp locations

DMX Adapter

-40°C to 70°C
(-40°F to 158°F)
storage maximum
is 85°C (185°F)

5-100%, condensing,
non-corrosive

suitable for
damp locations

Weights and Dimensions

Product

Weight

Dimensions

Notes

kg

lb

mm

in

Lyda lamp head

2.3

5

1027x104x75

40.4x4x3

Installs suspended

LED driver

1.05

2.3

218x68x39

8.6x2.7x1.5

Includes mounting
flange

DMX Adapter

0.2

0.4

90x38x27

3.5x1.5x1.0

Includes mounting
flange

Clearance

Lamp heads can be ganged together lengthwise, but do not install the Lyda lamp head
against walls or ceilings. Ensure a minimum clearance of 50 mm (2 in) between the lamp
head and other objects such as other lights, the ceiling, or wall surface for proper cooling.

Suspend the lamp head in free-air to allow for proper convection cooling.

Содержание Lyda

Страница 1: ...Lyda System Lamp Head and LED Driver Installation and User Manual Part Number 7431M1200 Rev A Released 2022 05...

Страница 2: ...trademarks both marked and not marked are the property of their respective owners For current and complete compliance and product information view the available documentation at rayngrowingsystems com...

Страница 3: ...amp Head 3 System Overview 4 Sample Systems 5 Cabling System 6 DMX Dimming 6 1 10 V Dimming 6 Accessories 7 Specifications 8 Environment 8 Weights and Dimensions 8 Clearance 8 Electrical 9 LED Driver...

Страница 4: ...yda Lamp Head 11 Install the LED Driver 13 Install the DMX Adapter 14 Power Up Procedure 15 Operation 15 Maintenance and Serviceability 16 Troubleshooting 16 LED Driver 16 Lyda Lamp Head 16 Install Le...

Страница 5: ...nd is suitable for mains power input in the range of 100 277 VAC 50 60 Hz It is dimmable using a 1 10 V input or by using an optional DMX Adapter that is also powered by the LED driver The lamp head o...

Страница 6: ...iceable Do not disassemble the driver in any way Independent lighting control gear Appareil de contr le d clairage ind pendant Safety extra low voltage device Dispositif de s curit tr s basse tension...

Страница 7: ...p head is not user replaceable and must be replaced only by a qualified technician Contact your RAYN Growing Systems provider for assistance Do not stare at the operating light source Ne pas regarder...

Страница 8: ...on both ends when installed 3 Lamp Cable Input Attach the lamp cable from the LED Driver to the lamp head input receptacle Rotate the locking ring counter clockwise to connect the Lamp Cable to the la...

Страница 9: ...s DMX Termination on the last device Control Cable Lyda Lamp Head Power Cable Line black or brown Neutral white or blue Ground green or green yellow Lamp Cable Control Cable Lyda Lamp Head DMX Adapter...

Страница 10: ...d so they are not subject to strain or damage DMX Dimming When utilizing the DMX Adapter to control the lamp head by a DMX control source connect the control cable provided on the DMX Adapter to the L...

Страница 11: ...US NEMA 5 15P 1 8 m 6 ft length L PCBEUS W6691 Power Cable Bare Ends US Color Code 1 8 m 6 ft length L PCBEIEC W6692 Power Cable Bare Ends IEC Color Code 1 8 m 6 ft length L LNM 7431K1002 Lens Medium...

Страница 12: ...is 85 C 185 F 5 100 condensing non corrosive suitable for damp locations Weights and Dimensions Product Weight Dimensions Notes kg lb mm in Lyda lamp head 2 3 5 1027x104x75 40 4x4x3 Installs suspended...

Страница 13: ...er Factor 0 99 0 98 0 95 Input AC Current 2 54 A 1 34 A 1 02 A Inrush Current I2 t 4 39 A2 s Standby Power 0 5 W max Typical Efficiency 89 5 92 5 93 The LED driver is a UL Class I apparatus This equip...

Страница 14: ...mp head features 120 beam angle as standard no lens installed A 60 medium beam spread lens is available for field installation and a 120 flat lens is available in cases where additional protection is...

Страница 15: ...et suivez les proc dures de Consignation D consignation prescrites par la norme NFPA 70E ou aux r glementations locales applicables Note For North American installation lamp head and LED Driver power...

Страница 16: ...For effective convection cooling and to prevent overheating do not install the lamp head vertically on its end Y X 3 If the LED driver has been previously installed connect the lamp cable from the dri...

Страница 17: ...ounterclockwise until finger tight 3 Connect the control cable optional use for 1 10 V dimming control If using the DMX Adapter connect the control cable from the DMX Adapter to the input connector on...

Страница 18: ...socket style connector Make the connections accordingly See Lyda System with DMX Dimming on page 5 for example system topology Contact your RAYN Growing Systems provider for additional system design...

Страница 19: ...evel signaled by the controller Set the appropriate control level on the controller and verify the respective light output WARNING Do not use this fixture with a damaged power cable cord set If the ca...

Страница 20: ...lable at rayngrowingsystems com contact Troubleshooting LED Driver To prevent damage to the LED driver an internal sensor monitors the temperature of the driver and decreases the output current as nee...

Страница 21: ...u will need to remove the end cap for this procedure Do not attempt this accessory installation with the lamp head suspended It is best accomplished on a flat work surface with all power and cables di...

Страница 22: ...18 Lamp Head and LED Driver Installation and User Manual...

Страница 23: ...Install Lens 19...

Страница 24: ...RAYN Growing Systems LLC All Rights Reserved Trademark and patent info rayngrowingsystems com ip All product information and specifications subject to change RAYN Growing Systems intends this documen...

Отзывы: