![Raymarine VCM100 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/raymarine/vcm100/vcm100_installation-instructions-manual_790257026.webp)
D11779-1
1
2
3
4
5
6
8
7
9
Item
Description
1
POWER OUT (Positive) — connect to the RED wire of
the power and data digital cable.
2
POWER OUT (Negative) — connect to the BLACK wire
of the power and data digital cable.
3
SCREEN — connect to the bare screen (drain) strands
of the power and data digital cable.
4
SCREEN — connect to your vessel’s RF ground
system.
5
POWER IN (Positive) — connect to the positive terminal
of the DC distribution panel or battery isolator switch.
Item
Description
6
POWER IN (Negative) — connect to the negative
battery terminal.
7
EMERGENCY STOP (Switch) — if you have the
optional VCM100 emergency stop button, remove the
wire bridging link from the VCM100 EMERGENCY
STOP terminals, and connect the emergency stop
button SWITCH wire to the VCM100 EMERGENCY
STOP SWITCH terminal.
8
EMERGENCY STOP wire bridging link— only remove
if fitting the optional emergency stop button.
9
EMERGENCY STOP (Screen) — if you have the
optional VCM100 emergency stop button, remove the
wire bridging link from the VCM100 EMERGENCY
STOP terminals, and connect the emergency
stop button SCREEN (drain) wire to the VCM100
EMERGENCY STOP SCREEN terminal.
26
HD and SuperHD Digital Open Array Installation instructions
Содержание VCM100
Страница 2: ......
Страница 4: ......
Страница 40: ...40 HD and SuperHD Digital Open Array Installation instructions ...
Страница 51: ...Chapter 7 Technical support Chapter contents 7 1 Raymarine technical support on page 52 Technical support 51 ...
Страница 57: ......
Страница 58: ...www raymarine com ...