Chapter 4: Disassembly and Reassembly
Type 150/150G/400/400G Course Computers Service Manual 83156-1
17
Type 150/400 Course Computers
the SIL pad is punctured the power devices are likely to be blown. This test is to check
whether the SIL pad is intact.
•
Using a DVM set to Ohms, touch one probe on the metal tab of the power device
and the other on the heatsink.
•
Check that the resistance measured is >500K
•
Repeat for all power devices along the right hand side of the PCB.
3.3. Detailed
Diagnosis
Before starting testing ensure that the following are connected to the Course Computer:
•
Fluxgate compass
•
Rudder reference
•
Control Head
•
330Ohm resistive load to the clutch terminals
•
Pathfinder Display connected via
NMEA 1
(do not connect the Pathfinder unit via
SeaTalk)
Unless otherwise stated, the following tests should be carried out with 12V applied to
the Course Computer
Step 1 - Power Checks
•
Check the voltages at the following locations are correct:
Testpoint Measured
Voltage
Type 150
Type 400
V
PWR
12V 12V
V12
12V 12V
3V
3.3V 3.3V
5V
4.9V – 5.2V
4.9 – 5.2V
VIN+12V
22.5 – 25V
22.5 – 25V
VADC
? ?