Raymarine ST70 Instrument Скачать руководство пользователя страница 32

26

ST70 Instrument User Reference Manual

Setting Vessel Type

CAUTION:  Vessel Type setting also affects other parameters

If you change the Vessel Type, you must then ensure all other parameters 

are set as you require before using the boat, as some other parameters 

change when the Vessel Type changes.

1. At the 

Advanced Options

 menu, use

 <

 and 

>

 to 

select 

Vessel Type

, then press 

ENTER

 to display 

the 

Vessel Type

 menu.

2. Use 

<

 and 

>

 to select the required Vessel Type, 

then press 

ENTER

 to save and exit the menu.

3. Use the 

Leaving Advanced Options

 procedure 

below, to return to the operational page.

Leaving Advanced Options

To leave the 

Advanced Options

 menu:

1. Press 

CANCEL

 to return to the 

Main Menu

.

2. Press 

CANCEL

 to return to the operational page.

Changing the time/date format

Note:  

Date and time information is available only if the ST70 instrument is receiving GPS data.

To change the format of either the time or date display:

1. Press 

MENU

 to display the 

Main Menu

 then use 

<

 or 

>

 to scroll to 

Display Settings

.

2. Press 

ENTER

 to show the 

Display Settings

 

menu.

3. Use 

<

 or 

>

 to scroll to the

 

Time & Date

 option. 

4. Press 

ENTER

. A summary of the time and date 

information is then displayed.

5.

P

ress 

ENTER

 again,

 

to display

 

the

 Time & Date 

menu.

6. Follow the 

Setting time format 

or 

Setting date 

format

 procedure (below), as appropriate.

Vessel Type

Inboard Speed Boat

i

Press ENTER to select

Selecting vessel type helps us to  
configure your system.

D10092-1

D9423-1

Time & Date

Press ENTER to select

Display Settings

Change the default time and 
date settings.

i

D9424-1

i

Time

11:01:03

Date

14/06/07

Time Offset

-1 Hrs

Time Format

24-hour

Date Format dd/mm/yy

These are your current settings.

Time & Date

Press ENTER to continue

D9778-1

Press ENTER to select

Time & Date

Set time format

81284_1.book  Page 26  Friday, May 4, 2007  7:29 AM

Содержание ST70 Instrument

Страница 1: ...ST70 Instrument User Reference Manual Document reference 81284 1 Date June 2007...

Страница 2: ...Raymarine SeaTalk SeaTalk2 and SeaTalkng are trademarks of Raymarine plc Book contents copyright Raymarine plc...

Страница 3: ...setting up 5 1 2 System functionality 5 SeaTalk 5 SeaTalk2 SeaTalkng 5 Power protocol 6 1 3 Commissioning requirement 6 WARNING Product installation operation 6 Chapter 2 Commissioning Procedures 7 2...

Страница 4: ...ion 25 3 2 Procedures 25 Changing the language or vessel type setting 25 Setting Language 25 Setting Vessel Type 26 CAUTION Vessel Type setting also affects other parameters 26 Leaving Advanced Option...

Страница 5: ...operating and setting up procedures Intended for all users ST70 User Reference Manual this document Intended for users in general and commissioning personnel in particular It describes Commissioning...

Страница 6: ...product improvement may change specifications without notice Therefore Raymarine cannot accept liability for any differences between the product and the accompanying documents Product disposal Waste...

Страница 7: ...defining the data content of each frame on the page Controls and buttons Used to Scroll to different operating pages Select choices on setup pages and buttons Used to Scroll to different menu options...

Страница 8: ...er installation what you see is dependent on whether the instrument requires commissioning or not Instruments requiring commissioning If the ST70 instrument is NOT part of a SeaTalkng system in which...

Страница 9: ...at initial switch on and you can use the instrument immediately In this case the new instrument will adopt the settings that already apply in the system POWER ON First switch on To normal operation F...

Страница 10: ...s Only resettable data types on the current operational page are available DISPLAY SETTINGS ENTER MENU Press release Hold down Hold down Press release User setup Normal Operation also part of initial...

Страница 11: ...trument is fitted with Raymarine SeaTalkng connectors but it can be connected to any of the following Raymarine systems using suitable adaptor cables as necessary SeaTalk SeaTalk2 SeaTalkng SeaTalk Wh...

Страница 12: ...rument that is NOT part of a SeaTalkng system in which at least one other ST70 instrument is already set up and working must be commissioned in accordance with Chapter 2 Commissioning Procedures befor...

Страница 13: ...type Set date and time format only if GPS is fitted Set correct local time only if GPS is fitted Set required data units Set the correct depth offset Set the correct magnetic variation Set the requir...

Страница 14: ...ic check of system parameters is carried out Autodetect results When the automatic checks are complete a Time Date summary page is displayed This shows the current values applied to your ST70 system N...

Страница 15: ...the format and return to the Time Date summary page 3 Press ENTER to select the Time Date setup menu Setting time format To set the required time format 1 With the Time Date setup menu displayed use a...

Страница 16: ...to either miles per hour kilometers per hour or knots Distance to either miles nautical miles or kilometers Depth to either feet fathoms or meters Wind speed to either knots or meters per second Headi...

Страница 17: ...urn to the first Units summary page 5 Press ENTER twice to display the Units setup menu 6 If you want to change any other units repeat steps 1 to 5 of this procedure Leaving units setup When all units...

Страница 18: ...ct depth offset 1 With any operational page displayed press MENU to display the Main Menu 2 Use or to scroll to Advanced Options then press ENTER 3 At the Advanced Options menu use or to scroll to Tra...

Страница 19: ...of the offset currently applied If the offset type is what you require and the value is correct for your boat press CANCEL to return to the Depth transducer menu then proceed from step 16 Otherwise p...

Страница 20: ...the Speed option 2 Press ENTER to select the Speed transducer setup menu 3 Use or to scroll to the Temperature Offset option 4 Press ENTER to display the Temperature Offset setup page 5 Using a suitab...

Страница 21: ...nd using your boat to ascertain the correct value of magnetic variation Note As the magnetic variation is dependent on your geographical location you may need to change the magnetic variation value du...

Страница 22: ...e and return to the Advanced Options menu 7 Press CANCEL to return to the Main Menu Now proceed to Changing response rate Changing response rate The response setting determines the rate at which data...

Страница 23: ...offset Water temperature Magnetic variation Ground wind calculation method Response rate When Dockside setup is complete return to the operational page then carry out a Seatrial calibration 2 2 Seatr...

Страница 24: ...you have A Wind transducer carry out the Wind transducer setup procedure below A Speed transducer carry out the Speed calibration on page 20 Wind transducer setup The wind transducer setup procedures...

Страница 25: ...er setup menu is displayed Alignment To carry out the wind vane alignment 1 With the Wind transducer setup menu displayed use or to scroll to Align Vane then press ENTER to display the Align Vane scre...

Страница 26: ...e boat speed ideally over the speed range of the vessel i e from stationary to top speed In order to take into account the changes in water flow characteristics across the hull for different speeds it...

Страница 27: ...o use SOG to set the correct speed 1 Carry out the Start calibration procedure above 2 Press to highlight the calibration factor field 3 In conditions of zero tide and zero current run your vessel at...

Страница 28: ...ation run then the calibration is correct at this speed so proceed from Manual calibration step 6 Not the same as the indicated speed i Calculate a new corrected calibration factor as follows ii Press...

Страница 29: ...h initiation message 3 Press CANCEL to select the Advanced options menu 4 Press CANCEL to select the Main Menu 5 Press CANCEL to return to normal operation 2 4 After commissioning When the dockside se...

Страница 30: ...24 ST70 Instrument User Reference Manual...

Страница 31: ...el Changing the screen colors Changing data units Switching off pages on and off and or changing page layout and content Setting local time Using the alarm clock 3 2 Procedures Changing the language o...

Страница 32: ...te and time information is available only if the ST70 instrument is receiving GPS data To change the format of either the time or date display 1 Press MENU to display the Main Menu then use or to scro...

Страница 33: ...formatbox then use or to select either dd mm yy or mm dd yy format as required 3 Press ENTER to save the setting and display the Time Date summary page 4 Use the Leaving time date setup procedure belo...

Страница 34: ...28 ST70 Instrument User Reference Manual...

Страница 35: ...le best possible performance from your Raymarine equipment guidelines are given in the installation instructions Always report any EMC related problem to your nearest Raymarine dealer We use such info...

Страница 36: ...f your ST70 instrument Be aware that radio signals transmitted nearby for example from another boat or shore station could affect the performance of your ST70 instrument If you are satisfied that the...

Страница 37: ...ion At faulty instrument carry out switch on procedure Check display brightness setting and adjust as necessary see Operating Guide Obtain technical assistance Return to normal operation Ensure all sy...

Страница 38: ...s and pod s are satisfactory Return to normal operation Return to normal operation Obtain technical assistance Data missing YES NO YES NO YES NO YES NO YES NO Refer to Chart 1 D9526 1 ST70 user troub...

Страница 39: ...relevant Software Version Number Hardware Version Number Bootloader Version Number Temperature Voltage Peak voltage Current Peak current Total hours run Are other instruments in system working OK Garb...

Страница 40: ...rt service on the world wide web and by telephone help line Please use either of these facilities if you are unable to rectify a problem If you intend seeking technical assistance please first use the...

Страница 41: ...or 1 603 881 5200 extension 2444 In the UK Europe the Middle East or the Far East call 44 0 23 9271 4713 voice 44 0 23 9266 1228 fax Help us to help you When requesting service please have the follow...

Страница 42: ...36 ST70 Instrument User Reference Manual...

Страница 43: ...ent Nominal dependent on screen brightness Maximum Not more than 220 mA Dimensions excluding studs 4 33 in W x 4 53 in H x 1 28 in D 110 mm x 115 mm x 32 5 mm Connections Two SeaTalkng Operating tempe...

Страница 44: ...38 ST70 Instrument User Reference Manual...

Страница 45: ...em HDOP Horizontal Dilution Of Position HMI Human Machine Interface see MMI MFD Multi Function Display MMI Man Machine Interface see HMI MOB Man Overboard NGCC New Generation Course Computer SOG Speed...

Страница 46: ...40 ST70 Instrument User Reference Manual...

Страница 47: ...its 10 date format 9 depth offset 11 ground wind calculation 15 initial switch on 7 language 8 local time 10 magnetic variation 15 response rate 16 time format 9 vessel type 8 water temperature 14 Doc...

Страница 48: ...9 26 vessel type 8 water temperature 14 wind vane alignment 19 Speed transducer calibration 20 manual calibration 22 set to SOG 21 start 21 Switch on day to day 2 initial 2 7 System operation 5 6 T Te...

Отзывы: