63
Appendix 2: SPX-5R Drive system
specifications
Course Computer
Drive
Nominal supply voltage
12 V dc (From course computer only)
(20 A fuse protection at distribution panel)
(15 A thermal circuit breaker protection at distribution panel)
Operating voltage range
11 V to 16 V DC
Current consumption (maximum)
200 mA
Rate Gyro
Built in
Environmental conditions:
• operating temperature
• storage temperature
• relative humidity limit
• water protection
-10°C to 50°C (14°F to 122°F)
-20°C to 65°C (-4°F to 149°F)
85% Relative Humidity (non condensing)
water ingress protection to IPX6, when mounted vertically
Dimensions:
Width: 240 mm (9
7
/
16
“), Height: 170 mm (6
11
/
16
“),
Depth: 55 mm (2
3
/
16
“)
Inputs
Fluxgate Compass, NMEA 0183 v3.01, SeaTalk (x2), SeaTalk
ng
,
power
Outputs
NMEA 0183 v3.01, SeaTalk (x2), drive motor, SeaTalk
ng
Raymarine drive compatibility:
Drive (as supplied with product)
Drive motor output:
5 A nominal
10 A peak
SeaTalk output
2A at 12 V (fuse protected at 2A)
NMEA 0183 v2.3 inputs/outputs
Appendix 1:, NMEA 0183 sentences
NMEA fast heading output
HDG
5 Hz 0.1° resolution
Fuses
Power Terminals
SeaTalk Terminals
Standard automotive blade fuses to protect:
15 A
2 A
EMC compliance:
Europe 2004/108/EC (EMC)
Australia and New Zealand: C-Tick, Compliance Level 2
Nominal supply voltage
12 V dc
Operating voltage range
10 V to 16 V dc
Содержание SmartPilot X-5R
Страница 1: ...SmartPilot X 5R Drive Installation Setup Document reference 87128 1 Date December 2010...
Страница 6: ...iv SmartPilot X 5R Drive Installation and Setup Guide...
Страница 14: ...6 SmartPilot X 5R Drive Installation and Setup Guide...
Страница 38: ...30 SmartPilot X 5R Drive Installation and Setup Guide...
Страница 56: ...48 SmartPilot X 5R Drive Installation and Setup Guide...
Страница 70: ...62 SmartPilot X 5R Drive Installation and Setup Guide...
Страница 74: ...66 SmartPilot X 5R Drive Installation and Setup Guide...