30
Pathfinder Radar Scanners
3. Referring to the following illustration, remove the cable gland
nut, washer and grommet from the watertight gland, where the
inter-unit cable will enter the base.
4. Slide the cable through the gland nut, washer and grommet, then
into the base. Clamp into position, ensuring the section of main
cable covered in yellow heat shrink is clamped.
5. The cable is supplied prepared and ready to fit to the signal and
power connectors. If you need to cut the cable to length, strip off
the protective outer sleeve then use the supplied kit to prepare the
cable as detailed in the following illustration
D4575-2
20mm (0.8in)
40mm (1.6in)
20mm (0.8in)
5mm (0.2in)
5mm (0.2in)
Heatshrink
154_4.book Page 30 Wednesday, October 25, 2000 3:02 PM