background image

7.1 User calibration

The i60 CH instrument display is a repeater display
and as such does not require calibration, the steps
below apply to the calibration of the i60 Wind
instrument only.

User calibration options include:

• Wind angle offset — Assigns an offset to the wind

angle readings.

• Units for Wind speed readings — Assigns the unit

of measure used for wind speed related readings

Automatic Linearization

The wind transducer can linearize itself automatically
under certain conditions.

For Automatic Linearization to be performed

CAL

must be flashing on the digital display. CAL is
displayed for approximately 30 seconds after power
on under the following conditions:

• At first power on, after installation

• At power on, after a factory reset.

To perform the automatic linearization the vessel will
need to be underway, with sufficient space to turn in
large circles unhindered. The wind speed must be
sufficient to hold the vane to wind whilst the vessel is
turning. The vessel must be turned slowly through at
least 2 complete circles.

x 2

D12415-2

This procedure automatically linearizes the wind
vane. A successful linearization is indicated by the
digital display flashing and a buzzer sounding three
beeps

Accessing the User Calibration Menu

The User Calibration Menu can be accessed by
following the steps below.

During normal operation:
1. Press and hold the

Display

and

True / App

buttons at the same time for approximately
2 seconds, until the User Calibration page is
displayed.

+

D12488-2

1

0

15

20

25

30

35

40

45

50

55

60 5

2

Disp

lay

T

rue /App

Aligning the wind transducer

From the User Calibration Menu:
1. Press the

Display

button until the

Wind Angle

Offset

page is displayed (1 press from the

User

Calibration

page).

D12489-2

Disp

lay

2. Sail your vessel directly into the wind and adjust

the analog pointer to zero, using the

VMG

and

Tack

buttons.

D12490-2

V

MG

T

a ck

The VMG button will decrease the current value
and the Tack button will increase the current
value. As you do this, the wind angle offset
shows the amount of correction you have applied.

3. To exit the User Calibration Menu at any time

press and hold the

Display

and

True / App

buttons at the same time for approximately 2
seconds.

Selecting the unit of measure for wind speed
readings

From the User Calibration Menu:
1. Press the

Display

button until the

Wind Speed

Units

page is displayed (2 presses from the

User

Calibration

page).

D12491-2

Disp

lay

2. Use the

VMG

or

Tack

buttons to select the

required unit of measure for wind speed readings.
The available units of measure for wind speed
are:

KTS (default)

— Knots

M/S

— Meters per second

3. To exit the

User Calibration

pages at any time

press and hold the

Display

and

True / App

buttons at the same time for approximately 2
seconds.

38

i60

Содержание i60 ch wind

Страница 1: ...i60 W ind i60 CH W ind Installation and operation instructions English Date 06 2014 Document number 81342 2 EN 2014 Raymarine UK Limited T ack T rue App Display VMG...

Страница 2: ......

Страница 3: ...patents design patents patents pending or design patents pending Fair Use Statement You may print no more than three copies of this manual for your own use You may not make any further copies or dist...

Страница 4: ......

Страница 5: ...27 4 7 NMEA2000 connection 28 Chapter 5 Mounting 29 5 1 Mounting 30 5 2 Front bezel 31 Chapter 6 Getting started 33 6 1 Controls 34 6 2 Power 34 6 3 Data master 35 Chapter 7 Calibration 37 7 1 User ca...

Страница 6: ...6 i60...

Страница 7: ...able Do NOT remove the connector If the cable is cut it cannot be repaired Cutting the cable will also void the warranty Caution Service and maintenance This product contains no user serviceable compo...

Страница 8: ...ution Sun covers To protect your product against the damaging effects of ultraviolet UV light always fit the sun covers when the product is not in use Remove the sun covers when travelling at high spe...

Страница 9: ...issions it may contain In addition our policy of continuous product improvement may change specifications without notice As a result Raymarine cannot accept liability for any differences between the p...

Страница 10: ...10 i60...

Страница 11: ...Chapter 2 Handbook information Chapter contents 2 1 Document information on page 12 2 2 Parts supplied on page 13 2 3 i60 Product overview on page 13 Handbook information 11...

Страница 12: ...Depth Alarm Offset Reset Speed Trip Timer Reset T ack T rue App Disp lay VMG i50 i60 Depth Speed Wind system pack E70153 i50 Depth SeaTalkng instrument display P319 Thru hull Depth transducer i50 Spee...

Страница 13: ...App Dis play VMG 1 2 D12549 2 1 i60 Wind The i60 Wind instrument provides a 360 wind direction scale and can be used as a stand alone unit or as part of a SeaTalk or SeaTalkng network 2 i60 Close Haul...

Страница 14: ...14 i60...

Страница 15: ...patible transducers on page 16 3 3 Typical systems on page 17 3 4 System protocols on page 19 3 5 Tools required on page 19 3 6 Selecting a display location on page 20 3 7 Product dimensions on page 2...

Страница 16: ...ntenance of the system The diagram should include Location of all components Connectors cable types routes and lengths 3 2 Compatible transducers Instrument Wind Vane transducer The wind vane transduc...

Страница 17: ...I I L LO O T T D12373 1 12 V 24 Vdc 12 Vdc SeaT alkng 1 2 6 10 11 8 9 5 7 3 4 1 SeaTalkng instrument display 2 SeaTalkng pilot controller 3 i60 Wind instrument 4 Raymarine wind vane transducer 5 Rayma...

Страница 18: ...ourse computer providing 12 V dc power supply to SeaTalkng network 6 12 24 V dc power supply 7 Raymarine AIS transceiver 8 Raymarine SeaTalkng GPS 9 Man over board 10 SeaTalk to SeaTalkng converter 11...

Страница 19: ...SeaTalk2 devices can also be connected using the appropriate interfaces or adaptor cables as required NMEA 2000 NMEA 2000 offers significant improvements over NMEA 0183 most notably in speed and conn...

Страница 20: ...tion which allows proper routing and connection of cables Minimum cable bend radius of 100 mm 3 94 in is required unless otherwise stated Use cable supports to prevent stress on connectors Electrical...

Страница 21: ...away from any equipment which may shield the transducer or otherwise disturb the air flow Provide a horizontal mounting surface If a surface e g mast top is otherwise suitable but not horizontal make...

Страница 22: ...22 i60...

Страница 23: ...cabling guidance on page 24 4 2 Power connection on page 24 4 3 SeaTalkng connections on page 25 4 4 Transducer connections on page 26 4 5 iTC 5 connection on page 26 4 6 SeaTalk connection on page 27...

Страница 24: ...t lights Always route data cables as far away as possible from other equipment and cables high current carrying ac and dc power lines antennae Strain relief Ensure adequate strain relief is provided P...

Страница 25: ...de of the power connection point is equal SeaTalkng power cables Part number Description A06049 SeaTalkng power cable 4 3 SeaTalkng connections The unit has 2 x SeaTalkng connectors on the rear for co...

Страница 26: ...When fitting the new spade connectors prepare the cables as detailed below 3 mm 6 mm 50 mm 1 2 D12359 1 1 Prepare the cable as shown in 1 above 2 Fold back the wire strands and insert into the new spa...

Страница 27: ...s 7 SeaTalk to SeaTalkng adaptor cables 8 Speed transducer 9 Depth transducer 10 12 24 V dc power supply 11 SeaTalk Course computer providing 12 V dc power to SeaTalk network 12 ST6002 pilot controlle...

Страница 28: ...ou have an isolation gateway between the two backbones Connecting NMEA2000 equipment to the SeaTalkng backbone 12V NM EA2000 SeaT alkng D12380 1 3 1 2 4 1 12 V dc power supply into backbone 2 SeaTalkn...

Страница 29: ...Chapter 5 Mounting Chapter contents 5 1 Mounting on page 30 5 2 Front bezel on page 31 Mounting 29...

Страница 30: ...ing a jigsaw cut along the inside edge of the cut out line 5 Ensure that the unit fits into the removed area and then file around the cut edge until smooth 6 Drill any required holes as indicated on t...

Страница 31: ...ezel doing so may cause damage 1 Using your fingers pull the bezel away from the unit at the top and side as shown in 2 The bezel will start to come away from the unit at the top and side 2 Now pull t...

Страница 32: ...32 i60...

Страница 33: ...Chapter 6 Getting started Chapter contents 6 1 Controls on page 34 6 2 Power on page 34 6 3 Data master on page 35 Getting started 33...

Страница 34: ...or to increase numeric values 6 2 Power Powering on the unit With power to the unit turned on but the unit switched off 1 Press and hold the Power button until the unit powers on and data is displayed...

Страница 35: ...ot check or change the instrument status of an i60 CH Wind display From the software version page 10 15 20 25 30 35 40 45 50 55 60 5 4 D12492 2 CAL CAL Display Display True App During normal operation...

Страница 36: ...36 i60...

Страница 37: ...Chapter 7 Calibration Chapter contents 7 1 User calibration on page 38 7 2 Intermediate calibration on page 39 7 3 Dealer calibration on page 39 Calibration 37...

Страница 38: ...n be accessed by following the steps below During normal operation 1 Press and hold the Display and True App buttons at the same time for approximately 2 seconds until the User Calibration page is dis...

Страница 39: ...o changes in wind angle data Display Response for wind speed readings Dictates the rate at which the instrument display responds to changes in wind speed data Display Response for VMG readings Dictate...

Страница 40: ...the wind speed Calibration Factor If you find that your wind speed readings deviate from a referenced wind speed source then a Calibration Factor can be applied to reduce the deviation From the User...

Страница 41: ...Note To exit the dealer calibration pages at any time press and hold the Display and True App buttons at the same time for approximately 2 seconds Calibration 41...

Страница 42: ...42 i60...

Страница 43: ...Chapter 8 Using your display Chapter contents 8 1 Pages on page 44 8 2 i60 Wind operation on page 44 8 3 Illumination on page 46 Using your display 43...

Страница 44: ...ers per second or as Beaufort scale values Velocity made good VMG information when vessel speed information is available on the network Tack angle when heading information is available on the network...

Страница 45: ...d Apparent wind readings should be identical D13142 1 3 1 2 1 Wind direction specified using compass points True Wind Direction TWD The compass direction that wind would appear to be blowing across th...

Страница 46: ...1 unit s backlighting level is adjusted all other units backlight level will also change When connected on a SeaTalkng network the unit can participate in group illumination and be assigned to a grou...

Страница 47: ...Chapter 9 Alarms Chapter contents 9 1 Alarms on page 48 Alarms 47...

Страница 48: ...rm D12555 2 HI The High apparent wind angle alarm sounds when the apparent wind angle equal to or more than the High apparent wind angle threshold The alarm sounds until silenced manually Low apparent...

Страница 49: ...s 10 1 Service and maintenance on page 50 10 2 Condensation on page 50 10 3 Routine equipment checks on page 51 10 4 Cleaning on page 51 10 5 Cleaning the display case on page 52 10 6 Cleaning the dis...

Страница 50: ...nd repair to authorized Raymarine dealers Unauthorized repair may affect your warranty 10 2 Condensation Certain atmospheric conditions may cause a small amount of condensation to form on the unit s w...

Страница 51: ...ng checks on a regular basis Examine all cables for signs of damage or wear and tear Check that all cables are securely connected 10 4 Cleaning Best cleaning practices When cleaning this product Do NO...

Страница 52: ...conditions condensation may appear inside the display screen This will not harm the unit and can be cleared by powering on the display for a short time 10 6 Cleaning the display screen A coating is ap...

Страница 53: ...roubleshooting Chapter contents 11 1 Troubleshooting on page 54 11 2 Instrument troubleshooting on page 55 11 3 Power up troubleshooting on page 56 11 4 Miscellaneous troubleshooting on page 57 Troubl...

Страница 54: ...ior to packing and shipping subjected to comprehensive test and quality assurance programs However if you experience problems with the operation of your product this section will help you to diagnose...

Страница 55: ...or connector fault Check security of SeaTalk SeaTalkng connections between units Check condition of SeaTalk SeaTalkng cables Isolate faulty unit by disconnecting units one by one A group of SeaTalk Se...

Страница 56: ...Possible causes Possible solutions Check relevant fuses and breakers Check that the power supply cable is sound and that all connections are tight and free from corrosion The system or part of it does...

Страница 57: ...lay Check that the power source is of the correct voltage and sufficient current Software mismatch on system upgrade required Go to www raymarine com and click on support for the latest software downl...

Страница 58: ...58 i60...

Страница 59: ...Chapter 12 Technical support Chapter contents 12 1 Raymarine customer support on page 60 12 2 Checking the software version on page 60 Technical support 59...

Страница 60: ...24 7900 Toll Free 1 800 539 5539 E mail support raymarine com In the UK Europe and the Middle East Tel 44 0 13 2924 6777 E mail ukproduct support raymarine com In Southeast Asia and Australia Tel 61 0...

Страница 61: ...Chapter 13 Technical specification Chapter contents 13 1 Technical specification on page 62 Technical specification 61...

Страница 62: ...rent 45 to 65 mA Typical Display only 200 mA Maximum Transducer connected LEN Refer to SeaTalkng reference manual for further information 4 Environmental Operating temperature 20 C to 55 C Storage tem...

Страница 63: ...Chapter 14 Spares and accessories Chapter contents 14 1 Spares on page 64 14 2 SeaTalkng cables and accessories on page 64 14 3 Converters on page 65 Spares and accessories 63...

Страница 64: ...ng Backbone Kit A25062 Includes 2 x 5 m 16 4 ft Backbone cable A06036 1 x 20 m 65 6 ft Backbone cable A06037 4 x T piece A06028 2 x Backbone terminator A06031 1 x Power cable A06049 SeaTalkng 0 4 m 1...

Страница 65: ...PX course computer or an ACU to a SeaTalkng backbone SeaTalk 3 pin to SeaTalkng adaptor cable 0 4 m 1 3 ft A06047 SeaTalk to SeaTalkng spur 1 m 3 3 ft spur A22164 SeaTalk2 5 pin to SeaTalkng adaptor c...

Страница 66: ...66 i60...

Страница 67: ...60928 ISO Commanded address 65240 NMEA Request group function 126208 NMEA Command group function 126208 NMEA Acknowledge group function 126208 PGN list Transmit PGN s group function 126464 PGN list Re...

Страница 68: ...68 i60...

Страница 69: ......

Страница 70: ...www raymarine com...

Отзывы: