background image

4.1 General cabling guidance

Cable types and length

It is important to use cables of the appropriate type
and length

• Unless otherwise stated use only standard cables

of the correct type, supplied by Raymarine.

• Ensure that any non-Raymarine cables are of the

correct quality and gauge. For example, longer
power cable runs may require larger wire gauges
to minimize voltage drop along the run.

Routing cables

Cables must be routed correctly, to maximize
performance and prolong cable life.

• Do NOT bend cables excessively. Wherever

possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).

100 mm (4 in)

200 mm (8 in)

• Protect all cables from physical damage and

exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or
doorways, or close to moving or hot objects.

• Secure cables in place using tie-wraps or lacing

twine. Coil any extra cable and tie it out of the way.

• Where a cable passes through an exposed

bulkhead or deckhead, use a suitable watertight
feed-through.

• Do NOT run cables near to engines or fluorescent

lights.

Always route data cables as far away as possible
from:

• other equipment and cables,

• high current carrying ac and dc power lines,

• antennae.

Strain relief

Ensure adequate strain relief is provided. Protect
connectors from strain and ensure they will not pull
out under extreme sea conditions.

Cable shielding

Ensure that all data cables are properly shielded
that the cable shielding is intact (e.g. hasn’t been
scraped off by being squeezed through a tight area).

Suppression ferrites

• Raymarine cables may be pre-fitted or supplied

with suppression ferrites. These are important for
correct EMC performance. If ferrites are supplied
separately to the cables (i.e. not pre-fitted), you
must fit the supplied ferrites, using the supplied
instructions.

• If a ferrite has to be removed for any purpose (e.g.

installation or maintenance), it must be replaced in
the original position before the product is used.

• Use only ferrites of the correct type, supplied by

Raymarine or its authorized dealers.

• Where an installation requires multiple ferrites to

be added to a cable, additional cable clips should
be used to prevent stress on the connectors due
to the extra weight of the cable.

Connections to other equipment

Requirement for ferrites on non-Raymarine cables

If your Raymarine equipment is to be connected
to other equipment using a cable not supplied by
Raymarine, a suppression ferrite MUST always be
attached to the cable near the Raymarine unit.

Содержание GA150a

Страница 1: ...GA150 Antenna Installation instructions English Date 05 2015 Document number 87230 2 EN 2015 Raymarine UK Limited...

Страница 2: ...s Inc All other trademarks trade names or company names referenced herein are used for identification only and are the property of their respective owners This product is protected by patents design p...

Страница 3: ...rmation utilized by the product supplied by third parties EMC installation guidelines Raymarine equipment and accessories conform to the appropriate Electromagnetic Compatibility EMC regulations to mi...

Страница 4: ...Electrical and Electronic Equipment WEEE Directive requires the recycling of waste electrical and electronic equipment Warranty registration It is important that you register your product to receive f...

Страница 5: ...at shown in the illustrations in this document depending on product variant and date of manufacture All images are provided for illustration purposes only Product documentation The following documenta...

Страница 6: ...bal Navigation Satellite System GNSS receiver D13078 1 The GA150 has the following features 10 m 33 ft fitted cable Low power consumption Surface or pole mountable Note When the Beidou GNSS becomes av...

Страница 7: ...lso useful for any future additions or maintenance of the system The diagram should include Location of all components Connectors cable types routes and lengths 3 2 GA150 MFD compatibility The GA150 a...

Страница 8: ...bit of appropriate size 1 Adhesive tape 1 Note The appropriate drill bit size is dependent on the thickness and material of the mounting surface 3 4 Warnings and cautions Important Before proceeding e...

Страница 9: ...ghts or other structures that could block line of sight to the sky As low as possible to keep the antenna as stable as possible The more stable the antenna the more effectively it will track satellite...

Страница 10: ...cables high current carrying ac and dc power lines antennae Strain relief Ensure adequate strain relief is provided Protect connectors from strain and ensure they will not pull out under extreme sea...

Страница 11: ...details for your external antenna refer to the documentation that accompanied the antenna Antenna cable length The GA150 is supplied with a fitted 10 m 33 ft cable The length of the antenna cable can...

Страница 12: ...ugh the mounting surface drill a 19 mm 0 75 in center hole OPTION B If the cable is to be routed from the side of the antenna i e above the mounting surface remove the two plastic tabs 1 obstructing t...

Страница 13: ...3 Route the antenna cable as follows i If you want to route the antenna cable directly down from the antenna option A feed it through the center of the pole mount adaptor and then down through the pol...

Страница 14: ...unit please contact Raymarine Technical Support for further advice GPS troubleshooting Problems with the GPS and their possible causes and solutions are described here Problem Possible causes Possibl...

Страница 15: ...off 2 Wipe unit clean with a damp cloth 3 If necessary use a mild detergent solution to remove grease marks Physical specification Dimensions Diameter 95 mm 3 7 in Height 30 mm 1 2 in Height includin...