1.
Waterproof fuse holder with 5 A inline fuse must be fitted (not supplied).
2. SeaTalkng ® power cable.
3.
Drain wire connection point.
Battery connection scenario A:
Suitable for a vessel with a common RF ground point. In this scenario, the power cable’s drain wire
should be connected to the vessel’s common RF ground point.
Battery connection scenario B:
Suitable for a vessel without a common RF ground point. In this scenario the power cable’s drain wire
should be connected directly to the battery’s negative terminal.
SeaTalkng ® Power cable extension
If you need to extend the length of the SeaTalkng ® power cable, ensure you use suitably rated cable
and that sufficient power is available at the SeaTalkng ® backbone’s power connection point:
• For power cable extensions, a
minimum
wire gauge of 16 AWG (1.31 mm
2
) is recommended. For
cable runs longer than 15 meters, you may need to consider a thicker wire gauge (e.g. 14 AWG
(2.08 mm
2
), or 12 AWG (3.31 mm
2
) ).
• An important requirement for all lengths of power cable (including any extension) is to ensure that
there is a continuous
minimum
voltage at the product’s power connector of 10.8 V dc, with a
fully flat battery at 11 V dc.
Important:
Be aware that some products in your system (such as sonar modules) can create voltage peaks at
certain times, which may impact the voltage available to other products during the peaks.
More information
It is recommended that best practice is observed in all vessel electrical installations, as detailed
in the following standards:
• BMEA Code of Practice for Electrical and Electronic Installations in Boats
• NMEA 0400 Installation Standard
64
Содержание Evolution EV-1
Страница 2: ......
Страница 4: ......
Страница 13: ...Chapter 2 Document information Chapter contents 2 1 Handbook information on page 14 Document information 13...
Страница 34: ...Item Description Quantity 4 Mounting screws 2 5 Document pack 1 34...
Страница 36: ...5 1 Dimensions EV 1 and EV 2 36...
Страница 37: ...5 2 Dimensions ACU 100 ACU 150 Product dimensions 37...
Страница 38: ...5 3 Dimensions ACU 200 ACU 300 ACU 400 38...
Страница 39: ...Chapter 6 Installation sequence Chapter contents 6 1 Installation checklist on page 40 Installation sequence 39...
Страница 54: ...54...
Страница 66: ...66...
Страница 80: ...Item Wire color ACU 100 ACU 150 1 Red 2 Blue 3 Green 4 Gray screen 80...
Страница 82: ...82...
Страница 104: ...104...
Страница 114: ...114...
Страница 115: ...Chapter 13 Operation Chapter contents 13 1 Evolution autopilot operation instructions on page 116 Operation 115...
Страница 128: ...128...
Страница 134: ...134...
Страница 138: ......
Страница 141: ......