background image

Chapter 1: Operation

1

Chapter 1: Operation

1.1 Introduction

The ST30 Round Bidata instrument is designed for the powerboat
market, and displays speed and depth information simultaneously on a
split LCD. The Bidata can also display trip and log distances, sound a
user-defined shallow alarm, and function as a repeater.

The instrument can be surface or flush mounted and fits the standard
85.7 mm (3 

3

/

8

 inch) diameter facia apertures, common on many sports

boats.

The Bidata uses an easy-to-install transom mount transducer (Biducer)
combining both speed and depth elements in a single housing.

If the Bidata is used in conjunction with a SeaTalk autopilot, the speed
input  provided by the instrument enhances the pilot's steering
performance.

bidata

depth

speed

depth

speed

D1601-2

The operating procedures are presented as a combination of flow charts
and text. Unless otherwise stated, the illustrated key presses are
momentary.

The Bidata can display depth and speed information in metric and
imperial units. These are set during basic calibration (see 

Chapter 4,

Calibration)

.

075_4c01.p65

11/04/01, 11:27

1

Содержание Autohelm ST30 Bidata

Страница 1: ...ST30 Round Bidata Owner s Handbook Document number 81075_4 Date 1stApril2001 075_4cov p65 11 04 01 11 27 1...

Страница 2: ...Copyright Raymarine Limited 2001 075_4cov p65 11 04 01 11 27 2...

Страница 3: ...neenvironment ThedesignandmanufactureofRaymarineequipmentandaccessories conformtotheappropriateElectromagneticCompatibility EMC standards butcorrectinstallationisrequiredtoensurethatperformance isnotc...

Страница 4: ...ii ST30RoundBidataOwner sHandbook 075_4pre p65 11 04 01 11 27 2...

Страница 5: ...h 2 Shallow alarm 2 Adjusting shallow depth 2 Silencing the shallow alarms 3 Turning shallow alarm ON and OFF 3 Offset 3 Default display 3 Loss of signal 3 1 3 Speed key functions 4 Speed 4 Trip dista...

Страница 6: ...ower via SeaTalk 13 3 5 Adding an independent lighting switch 13 3 6 Installing the Biducer transducer 14 Cable connections 14 3 7 Calibration requirement 14 Chapter 4 Calibration 15 4 1 Introduction...

Страница 7: ...ithout saving 19 Default display 20 4 3 Extended calibration 20 Calibration 21 Boat show 21 Depth and speed damping 21 Saving extended calibration 21 Exit extended calibration without saving 21 Specif...

Страница 8: ...vi ST30RoundBidataOwner sHandbook 075_4pre p65 11 04 01 11 27 6...

Страница 9: ...marineproduct Wearesureyour ST30instrumentwillgiveyoumanyyearsoftrouble freeoperation Thisinstrumentisdesignedtoprovidereliableperformance even underthemostdemandingconditions bidata depth speed depth...

Страница 10: ...a transducer is not included If any item is not present contact your Raymarine Dealer If the ST30 Round Bitata is to be flush mounted do not fit a display bezel ST30 Round Bidata instrument Sealing ga...

Страница 11: ...onmanysports boats TheBidatausesaneasy to installtransommounttransducer Biducer combiningbothspeedanddepthelementsinasinglehousing IftheBidataisusedinconjunctionwithaSeaTalkautopilot thespeed input pr...

Страница 12: ...hedepth feetormetres atwhichpoint audibleandvisualalarmswillbetriggered Thesealarmscanbe silencedbypressingthespeedordepthkey Adjusting shallow depth 1 Fromtheshallowdepthalarmdisplay pressdepthandspe...

Страница 13: ...played 2 PressdepthandspeedtogethermomentarilytoenterCAL mode 3 PressdepthtoswitchthealarmONorOFF 4 Press depthandspeedtogetherfor2secondstoexitCALmode Offset Thisisthedistance feetormetres fromtheBid...

Страница 14: ...tance Tripisthedistancecoveredbetweenpoweronandpoweroff Thiscan benauticalmiles NM kilometres KM orstatutemiles SM Resetting Trip Distance Pressandholdthe speedkeyuntilthetripdistanceiszeroed distance...

Страница 15: ...depth speed depth speed OFF L0 1 second TheBidatahasfourilluminationsettings off low L1 medium L2 and high L3 TheBidataautomaticallyreturnstonormaloperation5secondsafter thelastkeypress Iftheshallowde...

Страница 16: ...6 ST30RoundBidataOwner sHandbook 075_4c01 p65 11 04 01 11 27 6...

Страница 17: ...rmancefromyourRaymarine equipment guidelinesaregivenintheinstallationinstructions to enableyoutoensureminimuminteractionbetweendifferentitems ofequipment i e ensureoptimumElectromagneticCompatibility...

Страница 18: ...breaker fuse No speed information Biducer paddlewheel obstructed Poor Biducer cable connection or cable damaged Nodepthinformation Aerated water boat wakes or propeller wash Normal operation will ret...

Страница 19: ...eisnotcompromised Althougheveryefforthasbeentakentoensurethattheywillperform underallconditions itisimportanttounderstandwhatfactorscould affecttheoperationoftheproduct Theguidelinesgivenheredescribet...

Страница 20: ...eferriteneedstoberemovedduringinstallationit mustbereassembledinthesameposition Suppression ferrites Thefollowingillustrationshowstypicalcablesuppressionferritesfitted toRaymarineequipment Alwaysuseth...

Страница 21: ...esewillnotcauseahazardby weakeningcriticalpartsofthevessel sstructure Ifindoubt seek advicefromareputableboatbuilder 1 Ifappropriate usethetemplateprovidednearthebackofthisbook tomarktheintendedlocati...

Страница 22: ...tuds C bracket and thumbnutsasshown D1600 2 bidata depth speed depth speed 3 3 Connecting the power supply direct CAUTION Ensurethatthepowersupplyisprotectedbya5 Afuseorcircuit breaker 1 Plugthe2 m 6...

Страница 23: ...ntviathedaisyloomcable asshown 3 5Adding an independent lighting switch WhentheBidataispartofaSeaTalksystemthelightingiscontrolled fromthekeypadorfromanotherSeaTalkinstrumentonthebus Ifyouhaveanindepe...

Страница 24: ...vided Cable connections ThecablefromtheBiducerconsistsoffivecoreswhichshouldbe connectedtotheBidataasfollows Cablecolour Bidataconnection Green Green SPEED Screen Grey SPEED Red Red SPEED Blue Blue DE...

Страница 25: ...uresmustbecarriedoutbeforetheequipmentisused operationally tooptimisetheperformanceoftheinstrumentwiththe vessel Allkeypressesaremomentaryunlessotherwisestated EMC conformance Alwayschecktheinstallati...

Страница 26: ...onproceduretoturnonbasic calibration Offset entry Thisoptionisusedtoselectwhetherthedisplayedwaterdepthisfrom thesurfaceorbelowtheBiducer Seta 0 zero offset togivethedepthfromthetransducertothe seabed...

Страница 27: ...abledepthunitsaremetresorfeet Theseunitsaretoggled withthedepthorspeedkey Speed and log units TheavailablespeedandlogunitsareKmh Mph Kts SMandNM Theseunitsaretoggledwiththedepthorspeedkey Log calibrat...

Страница 28: ...bytwoto obtaintheaverage 4 AttheLOGcalibrationdisplay pressdepthandspeedtogether momentarilytoentereditmode 5 Enterthecorrectionfactor charteddistancedividedbythe average usingthedepthkeytoincreasethe...

Страница 29: ...y asarepeatingunitdisplayingspeedand depthinformationfromanotherinstrument PressspeedtotogglebetweenMASTER R0 andREPEATER R1 operatingmodes Inrepeatermode Youcannotenterbasiccalibration Youcannotviewo...

Страница 30: ...ress 4 3 Extended calibration Usethefollowingflowcharttocarryoutextendedcalibration Theextendedcalibrationfeaturesillustratedbelowarecycledusingthe depthkey bidata depth speed depth speed CAL 15 sec C...

Страница 31: ...ationprogramfordealeruseonly 1 ONand0 OFF Depth and speed damping Dampingcontrolstherateatwhichthedisplayeddataisupdated The selectablerange adjustedusingthespeedkey isbetween1and15 with1providingarap...

Страница 32: ...22 ST30RoundBidataOwner sHandbook 075_4c04 p65 11 04 01 11 27 22...

Страница 33: ...res 0 to 400 feet Speedrange 0to99 9knots mph orkph Trip 0to999nm sm orkm Log 0to5999nm sm orkm Shallowalarm 3to33feet 1to10metres Depthoffset 9 9 to 9 9 feet 4 0to 4 0metres Illumination 3levelsviaSe...

Страница 34: ...24 ST30RoundBidataOwner sHandbook 075_4spe p65 11 04 01 11 28 24...

Страница 35: ...ST30 Round Bidata Template Cut hole to 86 mm 3 8 in diameter max 3 Cut out shaded area only 075_4tem p65 11 04 01 11 28 1...

Страница 36: ...075_4tem p65 11 04 01 11 28 2...

Страница 37: ...mpellers impeller bearings and impeller shaft are specifically excluded from this Warranty Magnetrons Cathode Ray Tubes CRT TFT Liquid Crystal Displays LCD and cold cathode fluorescentlamps CCFL haile...

Страница 38: ...9 Ext 2333 or 1 603 881 5200 Ext 2333 Customer Support Telephone 44 0 23 9271 4713 Fax 44 0 23 9266 1228 Technical Support Telephone 1 800 539 5539 Ext 2444 or 1 603 881 5200 Ext 2444 Email techsuppor...

Отзывы: