0049-0117-100 DSP9612 Flash Poll Modem – User Guide
10/12/2011
Rev. F1
Page 14 of 44
SW1 DIP Switch Settings
SW1 is an 8-position DIP switch. Table 2-1 shows the modem switch
settings for DIP switch SW1. A description of the SW1 switch settings
follows the table.
Note:
SW1 settings apply for both high-speed fast-
poll and low-speed (FSK) modes
Table 2-1. Modem Switch Settings for DIP Switch SW1
Switch Settings
Switches
ON
OFF
(Default)
SW1-1
−
1-4: Transmit
Level (page 15)
(see Table 2-2 on page 15)
SW1-5: Receiver Dynamic
Range
(page 16)
−
10 to
−
43
dBm
+3 to
−
30
dBm
SW1-6: TX Cable Equalizer
(page 16)
Enabled Disabled
SW1-7: RX Cable Equalizer
(page 16)
Enabled Disabled
SW1-8: Anti-streaming
(page 16)
Active Inactive