background image

 

 
 

0049-0300-XXX                                                                MIU/Power Port Series  – USER GUIDE      

   

   08/04/2010 

Rev. A 

 

 

   Page 9 of 26

 

 

12.  OUTLINE DRAWING & MOUNTING 
 

 
 

 
 
 
 

Mounting Options: 

 

Part Number 

Description 

MIU/MTGK 

Surface Wall or Panel Mounting Kit 

MIU/RAIL 

MIU Din Rail Mounting Kit 

 
 
 
 
 
 

Содержание 2.4 MIU/PowerPort Series

Страница 1: ...0049 0300 XXX MIU PowerPort Series USER GUIDE 08 04 2010 Rev A Installation Operation Diagnostics for the MIU PowerPort Series 2 4 9 6 14 4 28 8 ...

Страница 2: ...0049 0300 XXX MIU PowerPort Series USER GUIDE 08 04 2010 Rev A Page i Raymar Information Technology Inc 7325 Roseville Road Sacramento CA 95842 800 695 1951 Fax 916 783 1952 ...

Страница 3: ...out notice and does not represent a commitment on the part of Raymar Telenetics Raymar Telenetics assumes no responsibility for any inaccuracies that may be contained in this User s Guide Raymar Telenetics makes no commitment to update or keep current the information in this User s Guide and reserves the right to make changes to this User s Guide and or product without notice No part of this manua...

Страница 4: ...FICATIONS Page 3 4 POWER MODES Page 4 5 MODEM SPECIFICATIONS Page 5 6 POWER CONNECTIONS Page 6 7 SERIAL DATA PORT PIN OUTS Page 7 8 DIP SWITCH SETTINGS Page 8 9 LED INDICATOR Page 8 10 AUTO RESET FEATURE Page 8 11 AUTO DIAL FEATURE Page 8 12 OUTLINE DRAWING MOUNTING Page 9 13 MODEM CONFIGURATION Page 10 14 FACTORY CONFIGURTION Page 11 15 DIAGNOSTICS Page 15 ...

Страница 5: ...on cord You should be aware however that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designed by the supplier Any repairs or alterations made by a user to this equipment or equipment malfunctions may give the telephone communications company cause to reque...

Страница 6: ...t The MIU PowerPort has been designed specifically for use in harsh environments In addition to an extended temperature range 40 to 85º C the MIU includes surge shock vibration and safety features superior to those of conventional commercial modems Power Supply The MIU PowerPort can be powered from a range of AC and DC power sources 5 VDC 12 VDC Battery 7 to 16 VAC or 8 to 16 VDC An optional 120 V...

Страница 7: ...IU PowerPort 9 6 9VDC 12VDC 24VDC 5VDC Pin 10 DTE Port 9VAC 80 6mA 84 7mA 84 0mA 182mA 69 4mA MIU1 PowerPort 14 4 9VDC 12VDC 24VDC 5VDC Pin 10 DTE Port 9VAC 128mA 107mA 91 4mA 239mA 165mA MIU PowerPort 28 8 9VDC 12VDC 24VDC 5VDC Pin 10 DTE Port 9VAC 149mA 171mA 104mA 243mA 193mA Surge Protection Power Supply 8kVrms Analog Line 5kVAC MIU2 4 9 6 Digital Line ESD 10kV Operating Temperature 40 to 85º ...

Страница 8: ...he modem will instantly wake up to full power by either an incoming ring signal or any transmit data TxD signal Approx 6mA Power Down If the modem is on hook for 30 seconds it will automatically turn off The modem will automatically turn on to full power within 400ms of receiving a DTR signal or an incoming call Approx 20µA The power mode is set by a dip switch on the Pony Express Modem Module ins...

Страница 9: ...is V 32 V 22bis V 22 Bell212A Bell 103 Modem Line Speed Asynch 2400bps 1200bps 300bps 2400bps 1200bps 300bps 14400bps 9600bps 4800bps 2400bps 1200bps 300bps 28800bps 19200bps 14400bps 9600bps 4800bps 2400bps 1200bps 300bps DTE Rates above Modem Line Speeds 19200bps 9600bps 4800bps 57600bps 38400bps 19200bps 115200bps 57600bps 38400bps 19200bps Error Correction Data Compression MNP 2 3 5 10 V 42 V ...

Страница 10: ... so either polarity is acceptable from the DC source The slide switch adjacent to the LED must be to the right side Toward the 2 0mm Jack DB25 Pin 10 A DC voltage may be applied at the 25 pin data connector DC only with the positive lead connected to pin 10 and the negative lead connected to Signal Ground on pin 7 This should be a regulated 5 VDC source The slide switch adjacent to the LED must be...

Страница 11: ...0049 0300 XXX MIU Power Port Series USER GUIDE 08 04 2010 Rev A Page 7 of 26 7 SERIAL DATA PORT PIN OUTS ...

Страница 12: ...n is lost for any reason it can be restored by dialing the modem and allowing it to ring 4 to 6 times The Auto Reset feature is enabled and disabled by a dip switch on the modem module Your MIU will have been shipped with the Auto Reset mode active unless otherwise specified at the time of ordering Please consult Raymar Telenetics if you wish to open up your MIU to disable Auto Reset 11 AUTO DIAL ...

Страница 13: ...XX MIU Power Port Series USER GUIDE 08 04 2010 Rev A Page 9 of 26 12 OUTLINE DRAWING MOUNTING Mounting Options Part Number Description MIU MTGK Surface Wall or Panel Mounting Kit MIU RAIL MIU Din Rail Mounting Kit ...

Страница 14: ...e time of order your modem will have left the Raymar Telenetics factory in the configuration detailed on the following pages The Raymar Telenetics factory configuration differs from the Rockwell default configuration as follows C0 Rockwell Default Carrier Detect CD always ON C1 Raymar Telenetics Factory Carrier Detect CD only ON when modem connected on hook S0 0 Rockwell Default Auto Answer OFF S0...

Страница 15: ... S08 002 S09 006 S10 014 S12 050 S14 AAH S16 00H S S18 000 S21 00H S22 76H S23 15H S25 005 S26 001 S27 40H S28 00H STORED PROFILE 0 B1 E1 L2 M1 Q0 V1 X4 Y0 C1 D0 G0 J0 L0 P0 Q0 R0 S0 X0 S00 001 S14 AAH S18 000 S21 00H S22 76H S23 17H S25 005 S26 001 S27 40H S28 00H STORED PROFILE 1 B1 E1 L2 M1 Q0 V1 X4 Y0 C0 D0 G0 J0 L0 P0 Q0 R0 S0 X0 S00 000 S14 AAH S18 000 S21 00H S22 76H S23 17H S25 005 S26 001...

Страница 16: ...05 S26 001 S36 007 S37 000 S38 020 S44 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D2 G0 J0 K3 Q5 R1 S0 T5 X0 S00 001 S02 043 S06 002 S07 050 S08 002 S09 006 S10 014 S11 095 S12 050 S18 000 S36 007 S37 000 S40 168 S41 195 S46 138 S95 046 STORED PROFILE 1 B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D2 G0 J0 K3 Q5 R1 S0 T5 X0 S00 001 S02 043 S06 002 S07 050 S08 002 S09 006...

Страница 17: ...05 S26 001 S36 007 S37 000 S38 020 S44 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D2 G0 J0 K3 Q5 R1 S0 T5 X0 S00 001 S02 043 S06 002 S07 050 S08 002 S09 006 S10 014 S11 095 S12 050 S18 000 S36 007 S37 000 S40 168 S41 195 S46 138 S95 046 STORED PROFILE 1 B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D2 G0 J0 K3 Q5 R1 S0 T5 X0 S00 001 S02 043 S06 002 S07 050 S08 002 S09 006...

Страница 18: ...25 005 S26 001 S36 007 S37 000 S38 020 S46 138 S48 007 S95 000 STORED PROFILE 0 B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D0 G2 J0 K3 Q5 R1 S0 T4 X0 S00 001 S02 043 S06 002 S07 030 S08 002 S09 006 S10 014 S11 095 S12 050 S18 000 S36 007 S37 000 S40 105 S41 003 S46 138 S95 000 STORED PROFILE 1 B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 C1 D0 G2 J0 K3 Q5 R1 S0 T4 X0 S00 001 S02 043 S06 002 S07 030 S08 002 S09 006 S10...

Страница 19: ...fic Tn command descriptions for termination actions T1 INITIATE LOCAL ANALOG LOOPBACK See Figure 2 When the AT T1 command is entered the modem goes on hook and configures itself for analog loopback DSR is turned off if S1 is in effect the analog loopback state is entered and the test timer is set to the value in S18 A connect result code is sent to the DTE and the test timer then begins its count ...

Страница 20: ...ok If S18 does not contain 0 the test is terminated after the number of seconds stored in S18 RESULT CODE DESCRIPTION OK After 2 second delay ERROR If any other self test is active T1 T6 T7 or T8 or if in idle state When test is terminated T4 GRANT REMOTE DIGITAL LOOPBACK RDL REQUESTS When in the on line state the modem will honor a remote digital loopback request from a distant modem if it occurs...

Страница 21: ...the remote end in three seconds it sends an ERROR result code to the DTE and returns to the command state The local modem sends the signal to release the remote digital loopback when the test is terminated The test may be terminated by the H0 Z or T0 command The test will also terminate when the test timer expires sending the modem to the command state or carrier is lost causing a NO CARRIER resul...

Страница 22: ...ed by loss of carrier or an H0 T0 or Z command and by the S18 timer running out RESULT CODES DESCRIPTION OK When command executed is started OK After error count is sent to DTE T1 T3 T6 T7 or T8 ERROR If not in on line command state ERROR If the RDL signal is not acknowledged T8 LOCAL LOOPBACK WITH SELF TEST See Figure 6 The modem should be on hook Enter AT T8 to configure the modem for analog loo...

Страница 23: ...0049 0300 XXX MIU Power Port Series USER GUIDE 08 04 2010 Rev A Page 19 of 26 ...

Страница 24: ...0049 0300 XXX MIU Power Port Series USER GUIDE 08 04 2010 Rev A Page 20 of 26 ...

Страница 25: ...0049 0300 XXX MIU Power Port Series USER GUIDE 08 04 2010 Rev A Page 21 of 26 ...

Страница 26: ... modem ERROR response if NO connection to remote modem In T1 modem Q will be 0 S86 CONNECTION FAILURE CAUSE S86 can help determine the cause of a connection failure When the modem issues a NO CARRIER result code a value is written to this register To read this register following the connection failure issue ATS86 CR The modem will report one of the following values 0 Normal hang up no error occurr...

Страница 27: ... 26 13 Other modem did not respond after many transmissions of the same message Modem made 10 attempts then hung up 14 Protocol violation occurred 15 Compression failure Note Multiple occurrences may contribute to a NO CARRIER message S86 records the first event that occurred ...

Страница 28: ...0049 0300 XXX MIU Power Port Series USER GUIDE 08 04 2010 Rev A Page 24 of 26 NOTES ...

Страница 29: ...ASE PRICE OF THE PRODUCT FOR ANY LOSS OF USE LOSS OF TIME INCONVENIENCE COMMERCIAL LOSS LOST PROFITS OR SAVINGS OR OTHER INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THIS RAYMAR PRODUCT TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW WITHOUT LIMITING THE FOREGOING RAYMAR SHALL HAVE NO LIABILITY FOR ANY DATA STORED IN OR USED WITH THE PRODUCT INCLUDING THE...

Страница 30: ...l number the serial number a description of the problem being encountered and the cause of the problem if known Please note that prior to authorizing a return a product support specialist may call to verify that the product is properly installed or may ask you to perform tests to insure that the product has actually failed The product must be properly packed and returned to Raymar Telenetics 7325 ...

Отзывы: