Rayleigh Instruments RI-ENERGYFLOW 3P Series Скачать руководство пользователя страница 19

3.6  Starting the Inverter

4.  User Interface

4.1  Led and key

4.2  LCD display

4.3  Factory setting

 
 
 

Figure 4-1 LED display

Description

Run

Fault

Pushbutton

Object

1

1

2

No.

Normal/Fault

Pac =

W

Vpv1

V

Pac =

W

Ipv1

X

A

Pac =

W

Va

X

V

Pac =

W

Ia

X

A

Pac =

W

Freq

X

Hz

Pac =

W

Event list

Pac =

W

Setting

Pac

X

W

Serial Number.

Model

Firmware

M: ×.×× S:×.××

SafetyCountry

××××××

E-today:

Kwh

Pac =

W

E-total:

Kwh

Pac =

W

Fault Code1

Pac =

W

Set Language

Pac =

W

Set Country

Pac =

W

...

Pac =

W

...

Pac =

W

Use

rs

etting

Factor

ys

etting

Set Language

Factory Set

Set Country

Factory Set

Mac Addr

xx

Set PF

Pac =

W

Clear Events

Pac =

W

Factory Settings

Pac =

W

Clear E-total

Pac =

W

PF

X

xxx

Pac =

W

Set MacAddr

Pac =

W

English

Factory Set

Portuguese

Factory Set

VDE4105

Factory Set

EN50549

Factory Set

...

Factory Set

Fault Code ...

Pac =

W

...

Pac =

W

...

Pac =

W

Factory Set

Pac =

W

xx

Pac =

W

Export Power

Pac =

W

...

Pac =

W

Vac Protect

Pac =

W

Fac Protect

Pac =

W

Set Input Mode

Pac =

W

Auto-test Italy

Pac =

W

...

Pac =

W

...

Pac =

W

...

Pac =

W

...

Pac =

W

Vpv2

X

V

Pac =

W

Ipv2

X

A

Pac =

W

Vb

X

V

Pac =

W

Vc

X

V

Pac =

W

Ib

X

A

Pac =

W

Ic

X

A

Pac =

W

Before turning on the inverter, please confirm the following:-

1 ) The three-phase (five wires - PE/L1/L2/L3/N) cable is correctly connected to the inverter AC side through an AC 
  circuit breaker;
2) The DC cable is correctly connected to the inverter DC side through a DC circuit breaker. Ensure the correct 
  connection of the two strings and their polarity.
3) Any unused terminals are covered.

1 ) Close the DC and AC circuit breakers;
2) If the solar panels are providing enough energy, the power module will function and the LCD panel will be lit;
3) If you are starting the inverter for the first time, the inverter needs to be commissioned. The process of 
  commissioning is described on page 17, chapter 4.3.
4) The inverter will then enter self-check mode and the LCD panel will simultaneously display the remaining time 
  of connection.
5)  The inverter should then enter normal operations mode and will feed electrical energy into the grid, and the LCD 
  panel will display the generated electrical energy.

Telephone  :  +44  (0)  1245  428500        

Email : [email protected]

17

Содержание RI-ENERGYFLOW 3P Series

Страница 1: ...428500 Email sales rayleigh com 3P SERIES 25 Solar Inverter User Manual RI ENERGYFLOW 3P SERIES 25 www rayleigh com Rayleigh Instruments Limited Raytel House Cutlers Road South Woodham Ferrers Chelmsf...

Страница 2: ......

Страница 3: ...Startingtheinverter 4 Userinterface 4 1 Ledandkey 4 2 LCDdisplay 4 3 Factorysetting 4 4 Settinglanguage 4 6 Self TestinaccordancewithCEI0 21 AppliestoItalyonly 5 Warranty 5 1 Warrantyclaimprocedure 5...

Страница 4: ...1 Introduction This manual describes solar inverters RI ENERGYFLOW 3P SERIES25 10KW 15KW 17KW 20KW 25KW These inverters are transformerless based inverter 1 3 Important safety information 1 1 Introduc...

Страница 5: ...erter Before installation Installation Disconnecting the inverter Operating the inverter should be used Functional safety parameters considered in each individual case Telephone 44 0 1245 428500 Email...

Страница 6: ...dimensions and electrical terminals of RI ENERGYFLOW 3P SERIES 25 10KW 15KW 17KW 20KW 25KW 382 00 510 00 185 00 Figure 2 2 wiring diagram of the inverter system 2 2 Electrical system design 1 EMC SO...

Страница 7: ...0 1000 165 2 2 2 30A 30A 17000 W 27 1 A 37500 W 2 2 30A 1 30A 25000 W 40 A RI ENERGYFLOW 3P SERIES 25 DC Input Data AC Output Data 17KW 25KW 15KW 20KW 10KW Protection Anti island Protection Over heat...

Страница 8: ...unication Relative Humidity Protection Grades Warranty EMC 506 386 185mm LCD 25 60 0 2W Transformerless 1 The maximum DC input current for RI ENERGYFLOW 3P SERIES 25 25KW is 37 5A Fan 5 7 10 years Fan...

Страница 9: ...Korea China W Brazil PEA PEA W MEA MEA W Tunisia Tunisia W 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Description National Regional Gr...

Страница 10: ...nectors for 17KW 20KW 25KW INVERTER 1 MOUNTING PANEL 1 PV CONNECTOR PV CONNECTOR SCREW 1 EXPANSION TUBE 4 QIG 1 QC PASS 1 FACTORY REPORT 1 AC connector 1 GPRS WIFI OPT Before installation and maintena...

Страница 11: ...ent 3 3 Installation position 1 Figure 3 3 Distance required of Invertors Figure 3 2 installation position No sun No rain No snow Sunlight Rain Snow 300mm 300mm 500mm 500mm 300mm Telephone 44 0 1245 4...

Страница 12: ...Drill 4 x 10mm holes in the wall as dimensions below Step 2 Affix the mounting bracket to the wall using the 4 expansion bolts supplied in the accessories bag Step 3 Hang the inverter on the wall moun...

Страница 13: ...t by using a crimping pliers 3 Separate the AC connector 4 Pass the crimped AC wire into the AC connector Figure 3 6 No Description Remark A B C D Protective layer diameter 15 25mm Length of stripped...

Страница 14: ...ear a click sound Figure 3 7 Figure 3 8 1 Use a screwdriver to press against the unlocked position and hold the wire nut and pull it back to complete the separation of the male and female ends 2 The f...

Страница 15: ...ing nut with one hand and rotate it in the direction of the mark and turn the nut in the opposite direction 4 Use a screwdriver to peel off the positions both sides indicated by the red circle to comp...

Страница 16: ...r successful connection information such as power generation and running state of the inverter can be viewed via the App on the phone For details please refer to the module user manual The block diagr...

Страница 17: ...NO or a normal close contact COM NC The relay is initially at the NC terminal and it will trip to another contact when a fault occurs Use LED indicators or other equipment to indicate whether the inv...

Страница 18: ...and their polarity 3 Any unused terminals are covered 1 Close the DC and AC circuit breakers 2 If the solar panels are providing enough energy the power module will function and the LCD panel will be...

Страница 19: ...t Set Country Factory Set Mac Addr xx Set PF Pac W Clear Events Pac W Factory Settings Pac W Clear E total Pac W PFX xxx Pac W Set MacAddr Pac W English Factory Set Portuguese Factory Set VDE4105 Fact...

Страница 20: ...4 4 Setting language 4 5 Setting modbus address 4 6 Self Test in accordance with CEI 0 21 Applies to Italy only Auto Test from screen 1 2 3 CEI 0 21 AutoTest Italy Pac 10000W 4 5 18...

Страница 21: ...5V 232 6V 223 8V 187ms 195 5V 213 0V 223 5V 1485ms 34 5V 36 2V 226 4V 190ms 50 20Hz 49 88Hz 49 98Hz 95ms 1 2 3 4 5 6 7 49 80Hz 49 88Hz 50 03Hz 88ms 51 50Hz 51 39Hz 50 04Hz 93ms 47 50Hz 48 01Hz 50 01Hz...

Страница 22: ...100 50 01 92 Pass Fmin 49 8 100 49 94 92 Pass 51 5 100 51 02 98 Pass Fmin 47 50 100 50 03 89 Pass Read Once the product has been installed and operational it is paramount to register the product to in...

Страница 23: ...tions Fault OFR Fault UFR LCD display Clearable Fault Fault 1 1 restarts 2 1 Grid is not connected 3 4 1 2 cooler environment 1 2 call local service 6 Troubleshooting and Maintenance 6 1 Troubleshooti...

Страница 24: ...EEPROM_R Fail SciCommLose BusFault CPU ADFault PLLFault AutoTestFail FanError LCD display Permanent Fault Fault 6 2 Maintenance NOTICE Otherwise Rayleigh Instruments shall not be held liable for any d...