13
1. REM/OFF/ON:
Key switch, the power switch of the laser. Insert the key;
either turn the key clockwise to the 'ON' position or counterclockwise to 'REM'
position will power on the laser.
2. POWER:
Power indicator, when the green light is on, it means the power
is on.
3. LASER:
Laser emission button, it’s a button with an annular LED
indicator (red color). When this button is pressed down, the product is ready for
emission, and the LED illumines. Press again will release the button, and disable
the emission.
4. ALARM:
Alarm indication: when the yellow light is on, it means that fault
occurs in the laser.
5. EMERGENCY STOP:
Press to turn off and lock the laser immediately.
Rotate clockwise to release the button. However, the laser must be powered on
again with the key switch to resume normal operation
。
4.2 Rear panel
Figure 7 shows the rear panel of the laser.
Figure 7 Rear Panel
1. CTRL-INTERFACE:
Control interface, this interface is a male DB25
connector and it’s multi-functional.
2. RS-232:
RS-232 interface
,
It is used for the connection between laser and
PC. Raycus provides RS-232 serial line.