background image

                        

 

               

User’s guide      Ytterbium Pulsed Fiber Laser      RFL-P10Q

/

P20Q/ P30Q/ P20QE/P50QB   Ver.: 2.0

   

                                                                                                                    

 

               

                                                                                                                         

 

 

6

 / 

9

 

 

 

1)

 

The  pump current of diode laser  and  the laser output  power  are controlled by setting the 

value of PIN1-PIN8 (TTL level). PIN1-PIN8 can be set from 0

255

corresponding to the 

laser output power from 0

100

  (the actual laser power may not be strictly linear with the 

setting value). The relationship between PIN value and output power is shown in Table 4: 

Table 4 Definition of power control PIN value 

 

Setting 1  Setting 2  Setting 3 

Setting 4 

Setting 5 

PIN 1 

PIN 2 

PIN 3 

PIN 4 

PIN 5 

PIN 6 

PIN 7 

PIN 8 

Current 

~50 % 

~75 % 

~87.5 %  ~93.75 % 

100% 

 

2)

 

Alarms  status:  Pins 11, 12, 16 and 21 are the alarm and status outputs. Pin 12 is reserved 

(always be high). These pins indicate the following device states. 

Table 5 Definition of alarm status. 

PIN 12 

PIN 11 

PIN 16 

PIN 21 

Alarm item 

×

 

Low 

Low 

Low 

Temperature alarm 

×

 

Low 

Low 

High 

Normal 

×

 

Low 

High 

Low 

Obligate alarm 

×

 

Low 

High 

High 

System alarm 

×

 

High 

Low 

Low 

Supply voltage 

×

 

High 

Low 

High 

Obligate alarm 

×

 

High 

High 

Low 

Obligate alarm 

×

 

High 

High 

High 

Obligate alarm 

 

3)

 

PIN 10

PIN 13 to PIN 15

PIN 24 are all digital GND. 

4)

 

PIN 20 is the pulse repeating rate signal (PRR, TTL level). If the PRR need to be changed 

during the work, it must be changed 5ms earlier than the EM signal turning into high. 

Содержание RFL-P20Q

Страница 1: ...编号 RFL P10Q P50QB 密级 阶段标记 页数 9 名称 RFL P10Q P20Q P30Q P20QE P50QB 脉冲光纤激光器英文使用说明书 会签 单位 第二事业部 编写 李科 校对 朱军 审核 施建宏 标审 李其军 批准 黄保 武汉锐科光纤激光技术股份有限公司 ...

Страница 2: ...RFL P10Q P20Q P30Q P20QE P50QB Ver 2 0 Ytterbium Pulsed Fiber Laser User s Guide RFL P10Q RFL P20QE RFL P20Q RFL P30Q RFL P50QB Wuhan Raycus Fiber Laser Technologies Co Ltd 2018 Proprietary information All rights reserved Issued 19 October 2018 ...

Страница 3: ...evice Before supplying the power to the device please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right Failure to connect power source correctly will cause damage to the device The device emits invisible 1060 1085nm wavelength light with average power 10W 50W Do not expose your eyes or skin to the radiation of the laser Do not take apart the...

Страница 4: ...vironmental requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 5 4 Operation Regulations 8 4 1 Pre inspection 8 4 2 Operation procedures 8 4 3 Cautions 8 5 Instructions for warranty return and maintenance 9 5 1 General warranty 9 5 2 Limitations of warranty 9 5 3 Service and repairs 9 ...

Страница 5: ...s Quantity Remark Fiber Laser module 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source 1 Caution Make sure the corresponding wires of the device are properly grounded 2 All the maintenance to the device should only be done by Raycus because there is no replacement or accessory provided with the device Please do not try to damage the labels or open...

Страница 6: ...ly works continuously 1 4 Specifications Table 2 10Q 20QE 20Q 30Q 50QB pulsed fiber laser specifications Pulsed fiber laser 10Q 20QE 20Q 30Q 50QB Wavelength nm 1060 1085 1060 1085 1060 1085 1060 1085 1060 1085 Polarization Random Random Random Random Random Optical isolator Yes Yes Yes Yes Yes Nominal average output power W 10 20 20 30 50 Single pulse energy mJ 1 20kHZ 0 66 30kHZ 1 20kHZ 1 30kHZ 1...

Страница 7: ...n in Fig 1 Figure 1 Dimension drawing of laser module Unit mm 2 Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm 2 2 Method of installation 1 Fix the module stable to the bracket and keep the laser in good ventilation 2 Connect the power line to 24VDC power and ensure enough DC output power Keep it clear ...

Страница 8: ...sure that the interface of the external controller matches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Fig 4 User s cont rolle r DB25 Controller interface Power supply wire Laser Module 24V Brown L N GND External GND 24V power supply 24V Blue Figure 4 Schematic of recommended electrical connection 4 The bending radius...

Страница 9: ...N No Name Description 1 8 D0 D7 Power Setting 8 bit Parallel port D0 is minimum bit and D7 is maximum bit Range 0 255 hexadecimal 0X00 0XFF 0 is minimum power and 255 is maximum power 10 13 15 24 25 Ground Digital GND 11 12 16 21 Laser alarms status see alarm codes in the table below 17 VCC 5VDC power supply input for independent operation of the guide laser and PCB 18 EE Emission Enable EE signal...

Страница 10: ...IN 4 0 0 0 0 1 PIN 5 0 0 0 1 1 PIN 6 0 0 1 1 1 PIN 7 0 1 1 1 1 PIN 8 1 1 1 1 1 Current 50 75 87 5 93 75 100 2 Alarms status Pins 11 12 16 and 21 are the alarm and status outputs Pin 12 is reserved always be high These pins indicate the following device states Table 5 Definition of alarm status PIN 12 PIN 11 PIN 16 PIN 21 Alarm item Low Low Low Temperature alarm Low Low High Normal Low High Low Obl...

Страница 11: ...guide Ytterbium Pulsed Fiber Laser RFL P10Q P20Q P30Q P20QE P50QB Ver 2 0 7 9 5 PIN 22 is the guide laser red diode on off signal High level switch on the guide laser while low level switch off the guide laser ...

Страница 12: ...ing range is from 30 KHz to 60 KHz For model P50QB the frequency setting range is from 50 KHz to 100 KHz 3 Laser marking checking For the device initial testing first turn the power down to zero without turning on the marking system after the device is successfully started Then draw a quadrate marking continuously while slowly increasing the power from zero to 100 at the same time Meanwhile use a ...

Страница 13: ...due to excessive use or not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage caused by fault operating is not warranted Accessories and fiber connectors are excluded in this warranty According to the warranty client should write to us within 31days since the defect is discovered...

Отзывы: