background image

 

 

 

 

@2020 Raycus Corporation 

 

 

Safety Information

 

 

Please read this instruction carefully and familiarize yourself with the information we have 

provided before you use the product. In this brochure, important operation procedures, safety and 

other  information  are  provided  for  you  and  all  future  users.  In  order  to  ensure  operating  safely 

and  optimal  performance  of  the  product,  please  act  according  to  following  warnings,  cautions 

and other information.

 

 

a)

 

Raycus  pulsed  fiber  laser  is  classified  as  a  high  power  Class  IV  laser  device.  Before 

supplying the power to the device, please make sure that the correct voltage of 24V DC 

is  connected  and  the  anode  and  cathode  are  right.

 

Incorrect  polarity  or  voltage  will 

harm severely the device. 

b)

 

The  device  emits  invisible  light  with  a  wavelength  from 

1060nm  to 

1085nm 

with average power of 100W. Do not expose  your eyes or skin to the radiation of the 

laser. 

 

c)

 

Do not take apart the device, because there are no replaceable accessories available for 

users to use. Any maintenance can only be proceeded in Raycus. 

 

d)

 

Do not look into the light output end directly. Use appropriate laser safety eye-wear(i.e. 

laser goggles) when operating the device. 

 

Safety labels and locations

 

 

Figure 1

 

Warning Signs 

 

The two labels above in Figure 1 are located on the top of the cover of the device, representing 

laser radicalization.

 

Содержание RFL-P100MX

Страница 1: ...A0 S RFL P100MX 100MX RFL P100MX JS02 20210315 20210316 20210322 20210322 20210322...

Страница 2: ...User Instruction RFL P100MX Wuhan Raycus Fiber Laser Technologies CO Ltd 2021...

Страница 3: ...make sure that the correct voltage of 24V DC is connected and the anode and cathode are right Incorrect polarity or voltage will harm severely the device b The device emits invisible light with a wav...

Страница 4: ...ions 1 1 4 Specifications 2 2 Mounting 4 2 1 Mounting dimensions 4 2 2 Method of installation 4 3 Control Interface 6 4 Operation Regulations 12 4 1 Pre inspection 12 4 2 Operation procedures 12 4 3 C...

Страница 5: ...ory inspection report 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24V DC 1V power source a Caution Make sure the corresponding wires of the device are properly groun...

Страница 6: ...make sure the power supply works continuously 1 4 Specifications Table 2 P100MX pulsed fiber laser specifications NO Characteristic Test condition Min Typ Max Unit 1 Mode of operation Pulsed 2 Polari...

Страница 7: ...5W 2 20 1 0 2 4W 500 100 105W 2000 100 105W 3 30 1 0 3 4W 330 100 105W 1000 100 105W 4 60 1 0 5 4W 200 100 105W 1000 100 105W 5 100 1 0 8 4W 125 100 105W 1000 100 105W 6 200 1 1 25 4W 80 100 105W 500...

Страница 8: ...on drawing of output isolator Unit mm The output head of the isolator is subject to the final factory product 2 2 Method of installation a Fix the module stable to the bracket and keep the laser in go...

Страница 9: ...external controller matches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Figure 5 Figure 5 Wiring diagram of recommended...

Страница 10: ...codes in Table 5 17 VCC 5VDC power supply input Providing power for inside isolate chip of DB25 to ensure that the input and output signal are valid 18 EE Emission Enable EE signal HIGH 4 5V Emission...

Страница 11: ...signal of the MO Pin19 is the input for the optical output signal The electrical level for both Pin18 and Pin19 are 5V Before turning on Pin 19 MO signal must be switched ON in other word the signal o...

Страница 12: ...factory which can meet the needs of most users Special needs shall be put forward in the customized contract g Definition of alarm signal Table 6 Definition of alarm signal Pin12 Pin11 Pin16 Pin21 Ala...

Страница 13: ...ition of Serial Communication Pin Name Description 2 Serial input The setting of the data bits synchronize with rising edge of the serial clock 3 Serial clock Serial clock frequency range 10KHz 100KHz...

Страница 14: ...4 The input data length is 4 bytes the first byte of instruction code should be 0x01 01h the second byte and the third byte are the value of the binary coding of laser duration for example 200 is the...

Страница 15: ...parameter should show up select Fiber in the category of the Laser Control panel follow that select IPG_YLPM and then close this window c Pulse duration can be modified by the Duration on the right s...

Страница 16: ...s showed in the Table 3 c Laser marking checking For the device initial testing first turn the power down to zero without turning on the marking system after the device is successfully started Then dr...

Страница 17: ...not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage caused by fault operating...

Отзывы: