Raychem QuickStat Скачать руководство пользователя страница 6

Sensor Testing

If the sensor is disconnected or short-circuited, the heating system is
turned off. Test your sensor according to the following resistance table:

Error Codes

E0: Internal error. The thermostat must be replaced.
E2: External sensor short-circuited or disconnected.

Sensor 

  Temp (˚C) 

Temp (˚F) 

Value (ohm)

 –10 

–14 

64000

 0 

32 

38000

 10 

50 

23300

 20 

68 

14800

 30 

86 

9700

QuickStat Installation & Operation Manual

6

Worldwide Headquarters 
Tyco Thermal Controls

300 Constitution Drive  
Menlo Park, CA 94025-1164
USA
Tel (800) 545-6258 
Fax (800) 596-5004
[email protected]
www.tycothermal.com

Canada
Tyco Thermal Controls

250 West St.
Trenton, Ontario Canada K8V 5S2
Tel (800) 545-6258
Fax (800) 596-5004

Important

:

All information, including illustrations, is believed to be reliable.

Users, however, should independently evaluate the suitability of each product for
their particular application. Tyco Thermal Controls makes no warranties as to the
accuracy or completeness of the information, and disclaims any liability regarding
its use. Tyco Thermal Controls' only obligations are those in the Tyco Thermal
Controls Standard Terms and Conditions of Sale for this product, and in no case
will Tyco Thermal Controls or its distributors be liable for any incidental, indirect,
or consequential damages arising from the sale, resale, use, or misuse of the
product. Specifications are subject to change without notice. In addition, Tyco
Thermal Controls reserves the right to make changes—without notification to
Buyer—to processing or materials that do not affect compliance with any applica-
ble specification.

© 2005 T

yco Thermal Controls LLC                     H57725   12/05

Tyco, Raychem, QuickNet and QuickStat are trademarks of Tyco Thermal Controls LLC
or its affiliates.

Содержание QuickStat

Страница 1: ...days of the week Offers 4 periods called events each day that you can set at different temperatures Comes with a preprogrammed schedule that is suitable for most installations However you can customize this program any time you wish Allows you to reset the thermostat to factory settings Changes the start time of a heating period automatically so that the desired temperature is reached at the time ...

Страница 2: ... box 1 Use a screwdriver to remove the cover 2 Mount the thermostat in the wall socket and re attached the cover Thermostat Controls and Display Symbols The following figure shows the thermostat controls The following figure shows the symbols that appear in the display window while you are programming Clock function Manual mode Time and temperature Day number 4 event symbol Wake Night Out Home swi...

Страница 3: ...appear If this does not occur check the installation 1 Press the RESET button to reset the GFCI The red light should disappear and the display will return to normal appearance 2 Press the OK button to cancel the previously set temperature 3 If the test fails check your heating cable and the thermostat If the GFCI trips in normal operation without pressing the TEST button there could be a ground fa...

Страница 4: ...rning thermostat off To turn the thermostat OFF press the DOWN button until you reach 41 F press the OK button then press the once more DO NOT USE THE TEST BUTTON ON THE GFCI TO SWITCH OFF THE HEATING SYSTEM The GFCI automati cally resets after a power outage Programming 4 event time and temperature The table below shows the default time and temperature settings how ever you can easily change each...

Страница 5: ...erature setting range of 41 F to 104 F can be limited to prevent a too high or too low temperature from being selected Set the maximum allowed temperature Use the UP or DOWN button to increase or reduce and the OK button to accept Next LoLi is displayed Press the OK button to continue Set the minimum temperature that the floor should never fall below Use the UP or DOWN button to increase or reduce...

Страница 6: ...ble Users however should independently evaluate the suitability of each product for their particular application Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product and in no ca...

Страница 7: ...urs de la semaine 4 périodes ou événements par jour pour le réglage de températures différentes Programme standard convenant pour la plupart des installations Ce programme peut être personnalisé à volonté Réinitialisation pour retrouver les réglages d usine du thermostat Préchauffage automatique pour que la température désirée soit atteinte à l heure programmée Règle la température du sol au moyen...

Страница 8: ...ctrique 1 À l aide d un tournevis retirer le couvercle 2 Monter le thermostat dans la prise murale et replacer le couvercle Commandes du thermostat et symboles affichés La figure ci dessous indique les commandes du thermostat La figure ci dessous illustre les symboles qui apparaissent sur l afficheur pendant la programmation Fonction horloge Mode manuel Heure et température Jour de la semaine Symb...

Страница 9: ... thermostat disparaît Si ce n est pas le cas vérifiez l installation 1 Appuyez sur le bouton RESET de réarmement du disjoncteur Le voyant rouge doit s éteindre et l affichage réapparaître 2 Appuyez sur le bouton OK pour annuler le changement de température de consigne 3 Si le résultat du test n est pas normal vérifiez le câble de chauffage et le thermostat Si le disjoncteur différentiel se déclenc...

Страница 10: ...on fonctionnement automatique Arrêt complet du chauffage Pour arrêter le chauffage appuyez sur le bouton MOINS jusqu à ce que la température atteigne 41 F puis appuyez sur le bouton OK et à nouveau sur N UTILISEZ PAS LE BOUTON TEST DU DISJONCTEUR DIFFÉRENTIEL POUR COUPER LE CHAUFFAGE Le dis joncteur différentiel se réarme automatiquement après une panne de courant Programmation Heures et températu...

Страница 11: ...04 F peut être limitée pour éviter que quelqu un sélectionne une température trop haute ou trop basse Pour régler la température maximum per mise appuyez sur les boutons PLUS ou MOINS pour augmenter ou réduire la température puis appuyez sur le bouton OK pour confirmer L afficheur indique LoLi Appuyez sur le bouton OK pour continuer Vous pouvez maintenant sélectionner la température minimale au de...

Страница 12: ...e s assurer indépendam ment que chaque produit convient à l application envisagée Tyco Thermal Controls ne peut affirmer que ces renseignements sont exacts et complets et en conséquence décline toute responsabilité quant à leur utilisation Les seules obligations acceptées par Tyco Thermal Controls sont celles qui figurent explicitement dans les conditions générales de vente du produit en question ...

Отзывы: