Raychem QuickStat Скачать руководство пользователя страница 1

QuickStat 

®

 Thermostat 

Installation & Operation Manual

General Information

Use of this Manual

This manual covers the installation and operation of the Raychem

® 

QuickStat

®

  thermostat and must be used with the following document: 

• 

QuickNet

®

 System Installation Manual

 (H57704)

 Important:

 For the Tyco Thermal Controls warranty and agency approv-

als to apply, the instructions included in this manual and product pack-

ages must be followed.

Features

QuickStat is an electronic thermostat that must be used with the 

Raychem QuickNet floor heating mats. 

QuickStat provides the following features:

•  Includes an integrated Class A, Ground-fault Circuit Interrupter (GFCI) 

at 120 V.  If the QuickStat is powered at 208 V or 240 V, a separate 

GFCI must be used.

•  Operates at 120 V, 208 V, 240 V 50/60 Hz.

•  Switches on your heating system at predetermined times on different 

days of the week.

•  Offers 4 periods (called events) each day that you can set at different 

temperatures.

•  Comes with a preprogrammed schedule that is suitable for most 

installations. However, you can customize this program any time you 

wish.

•  Allows you to reset the thermostat to factory settings. 

•  Changes the start time of a heating period automatically so that the 

desired temperature is reached at the time that you set. 

•  Controls the temperature of the floor through a temperature sensor 

that is placed in the floor construction.

Specifications

Approvals

C

US

LISTED

 2D03

E255369

 

Technical Data

Supply Voltage 

120 V, 208 V, 240 V ±15%, 50/60 Hz

Maximum switching current  15 A 

Wiring 

12 AWG to 22 AWG

GFCI 

Class A, 5 mA trip level (at 120 V only)

Temperature control range  

40 to 104°F (5 to 40°C)

Ambient temperature range
     Thermostat  

32 to 104°F (0 to 40°C)

   GFCI  

– 31 to 149°F (– 35 to 65°C)

A

B

C

Kit contents

QuickStat thermostat

Mounting screws

Floor temperature sensor 10 ft (3m)

Содержание QuickStat

Страница 1: ...at predetermined times on different days of the week Offers 4 periods called events each day that you can set at different temperatures Comes with a preprogrammed schedule that is suitable for most installations However you can customize this program any time you wish Allows you to reset the thermostat to factory settings Changes the start time of a heating period automatically so that the desired...

Страница 2: ...d lead braid ground to the supply ground in the electrical junction box 4 Connect the floor temperature sensor to the screw less terminals marked Sensor Push on the terminal spring with a screwdriver and insert the wires Mounting the thermostat in the electrical box 1 Use a screwdriver to remove the cover 2 Mount the thermostat in the wall socket and re attached the cover Thermostat Controls and D...

Страница 3: ...ns disappear If this does not occur check the installation 1 Press the RESET button to reset the GFCI The red light should disappear and the display will return to normal appearance 2 Press the OK button to cancel the previously set temperature 3 If the test fails check your heating cable and the thermostat If the GFCI trips in normal operation without pressing the TEST button there could be a gro...

Страница 4: ...rning thermostat off To turn the thermostat OFF press the DOWN button until you reach 41ºF press the OK button then press the once more DO NOT USE THE TEST BUTTON ON THE GFCI TO SWITCH OFF THE HEATING SYSTEM The GFCI automati cally resets after a power outage Programming 4 event time and temperature The table below shows the default time and temperature settings how ever you can easily change each...

Страница 5: ... days Maximum and minimum allowed temperature range The temperature setting range of 41ºF to 104ºF can be limited to prevent a too high or too low temperature from being selected Set the maximum allowed temperature Use the UP or DOWN button to increase or reduce and the OK button to accept Next LoLi is displayed Press the OK button to continue Set the minimum temperature that the floor should neve...

Страница 6: ...t All information including illustrations is believed to be reliable Users however should independently evaluate the suitability of each product for their particular application Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls St...

Страница 7: ... des heures prédéterminées pour les différents jours de la semaine 4 périodes ou événements par jour pour le réglage de températures différentes Programme standard convenant pour la plupart des installations Ce programme peut être personnalisé à volonté Réinitialisation pour retrouver les réglages d usine du thermostat Préchauffage automatique pour que la température désirée soit atteinte à l heur...

Страница 8: ...stat aux bornes marquées L1 L et L2 N Pour installation à 120 V s assurer que le fil du neutre soit raccordé à la borne L2 N 2 Raccordez le fil froid du système de chauffage aux bornes marquées Load 15 A Max 3 Brancher le faisceau de fils froids du système de chauffage de sol terrre à mise à la terre de l alimentationdans la boîte de jonction électrique 4 Brancher la sonde de température du planch...

Страница 9: ...ostat disparaît Si ce n est pas le cas vérifiez l installation 1 Appuyez sur le bouton RESET de réarmement du disjoncteur Le voyant rouge doit s éteindre et l affichage réaparaître 2 Appuyez sur le bouton OK pour annuler le changement de température de consigne 3 Si le résultat du test n est pas normal vérifiez le câble de chauff age et le thermostat Si le disjoncteur différentiel se déclenche en ...

Страница 10: ...rend son fonction nement automaique Arrêt complet du chauffage Pour arrêter le cauffage appuyez sur le bouton MOINS jusqu à ce que la température atteigne 41 ºF puis appuyez su le bouton OK et à nouveau sur N UTILISEZ PAS LE BOUTON TEST DU DISJONCTEUR DIFFÉRENTIEL POUR COUPER LE CHAUFFAGE Le dis joncteur différentiel se réarme automatiquement après une panne de courant Programmation Heures et temp...

Страница 11: ...F à 104 ºF peut être limitée pour éviter que quelqu un sélectionne une températures trop haute ou trop basse Pour régler la température maximum ermise appuye sur les boutons PLUS ou MOINS pour augmenter ou réduire la tempéature puis appuyez sur le bouton OK pour confirmer L afficheur indique LoLi Appuyez sur le bouton OK pour continuer Vous pouvez maintenant sélectionner la température minimale au...

Страница 12: ...spécifications techniques peuvent être modifiées sans préavis De plus Tyco Thermal Controls se réserve le droit de changer ses procédés de fabrication et les matériaux entrant dans la composition du produit sans en aviser l acheteur dans la mesure où cela n affecte pas la conformité à l une quelconque des spécifications applicables Tyco QuickNet and QuickStat sont des marques de commerce de Tyco T...

Отзывы: