background image

DC12-48-60-0-25E     

INSTALL INSTRUCTIONS        

www.raycapsurgeprotection.com

©Raycap  •  All rights reserved

(320-0666)  Rev.B

Page 2 of 10

1.0 

Copyright

©

 Raycap, Inc. 2013 - All Rights Reserved

1.1 

Disclaimer

The information in this document is subject to change without notice and describes only the 

product deined in the introduction of this documentation. This documentation is intended for the 

use of Raycap customers only for the purposes of the agreement under which the document is 

submitted, and no part may be used, reproduced, modiied or transmitted in any form or means 

without the prior written permission of Raycap. The documentation has been prepared to be used 
by professional and properly trained personnel, and the customer assumes full responsibility when 
using it. Raycap welcomes customer comments as part of the process of continuous development 
and improvement of the documentation.

Raycap has made all reasonable efforts to ensure that the instructions contained in this document 
are adequate and free of material errors and omissions. Raycap will, if deemed necessary explain 
issues which may not be covered by this document.

The contents of this document are subject to revision without notice due to continued progress in 
methodology, design and manufacturing. Raycap shall have no liability for any error damage of any 
kind resulting from the use of this document.

1.2 

Warnings

Please read this manual prior to use to become familiar with the product’s numerous features and 
operating procedures. To maintain the maximum degree of safety, follow the sequences as outlined. 

 

Before using the product, read all instructions and cautionary markings on the product and on any 
equipment connected to the product. 

CAUTION – Unless otherwise noted, product usage that is not recommended or sold by the product 

manufacturer can result in risk of ire, electric shock, or injury to persons. 

CAUTION – Do not operate the product if it has been damaged in any way. Return damaged 
products to their manufacturer for repair or replacement. 

CAUTION – Do not disassemble the product as incorrect reassembling can risk electrical shock  

or ire. 

WARNING – Disconnect or disable the DC power source to the product prior to beginning its 
installation. Ensure that the DC power source to the product remains de-energized until the 

completion of the installation and after all connections have been veriied to be correctly conigured.

For conditions other than those described above, please contact a Raycap Account Representative 
at (208) 777-1166, (800) 890-2569 or www.raycapsurgeprotection.com

Thank you for choosing quality products from Raycap.

Содержание DC12-48-60-0-25E

Страница 1: ...www raycapsurgeprotection com Installation Instructions DC12 48 60 0 25E INSTALL INSTRUCTIONS DC12 48 60 0 25E ...

Страница 2: ......

Страница 3: ...s 1 Copyright 2 1 1 Disclaimer 2 1 2 Warnings 2 2 Introduction 3 3 OVP Package Contents 3 3 1 Prerequisites 3 3 2 Tools 3 4 Port Deinitions OVP Deinitions 4 5 Installing 2 Conduit 5 6 Installing Alarm Cable Coniguring alarm daisy chain 5 7 Installing Ground Cable 7 8 Installing DC Trunk Cables 8 48V power supply 48V to tower roof ...

Страница 4: ... continued progress in methodology design and manufacturing Raycap shall have no liability for any error damage of any kind resulting from the use of this document 1 2 Warnings Please read this manual prior to use to become familiar with the product s numerous features and operating procedures To maintain the maximum degree of safety follow the sequences as outlined Before using the product read a...

Страница 5: ...uring Strikesorb SPD technology signiicantly enhance the reliability availability of the RRH site by providing superior electrical protection at the RRH and BBU and also enable lexible iber optic and power cable management solutions 3 0 OVP Package Contents 1 each OVP Enclosure 4 each Fitting 2 PVC Terminal Adapter Male 2 each Ground lugs 6 AWG with inspection port 3 1 Prerequisites This Document ...

Страница 6: ... to 1 0 AWG Double lug ground 6 AWG Can be rotated vertically or horizontally Compression Lug 2 14 AWG 2 conduit Ground 0 2 0 39 wire Procedure Port Deinitions 4 1 See illustration to identify Base Port Assembly Deinitions Note Optional glands and inserts are included in hardware kit shipped with the DC12 48 60 0 25E OVP Deinitions 4 2 2 Conduit 2 Conduit Ground Ground ...

Страница 7: ...TIONS DC12 48 60 0 25E Procedure Installing conduit 5 1 Open cover loosening the two screws on the front of unit 5 2 Install 2 conduit into the conduit ports on bottom of unit as needed Installing alarm cable 6 1 Connect wires according to your established color guide Connect alarm wires to alarm lugs ...

Страница 8: ...hain 6 2 6 3 Alarm installation complete If less than 12 modules are powered disconnect termination loop of Daisy Chain and install into alarm wire assembly at the last powered module Position of termination loop for 6 module connection Typical alarm Daisy Chain when all 12 modules are powered Position of termination loop for 12 module connection ...

Страница 9: ...m Raycap All rights reserved 320 0666 Rev B Page 7 of 10 INSTALL INSTRUCTIONS DC12 48 60 0 25E Procedure Installing ground cable 7 1 Feed ground cable through ground port and connect to ground lug 7 2 Ground installation complete ...

Страница 10: ...66 Rev B Page 8 of 10 Procedure Installing DC trunk cable 48V power supply 8 1 Feed DC trunk cable through conduit port hole Connect wires according to AT T color guide Installing DC Jumpers 48V to tower roof 8 2 Feed DC trunk cable through conduit port hole Connect wires according to AT T color guide ...

Отзывы: