9
Properly installed and operated, this cooker will not emit
fumes.
Occasional fumes from de-ashing and re-fuelling may occur
but persistent fume emission must not be tolerated.
If fume emission does persist, then the following immediate
action should be taken:-
a) Open doors and windows to ventilate room.
b) Let the fire out or remove lit fuel from cooker.
c) Check for flue or chimney blockage, and clean if
required.
d) Do not attempt to relight fire until cause of fume has
been identified, and if necessary, seek professional
advice.
Part Number
Description
No Reqd
QWX
Boiler Thermostat
1
1/16182 T
Bottomgrate bars top
6
1/16182 B
Bottomgrate bars bottom
5
3/16272
Oven side firebricks
2
4/16273
Firebox side top firebricks
1
3/16271
Front firebrick
1
3/16274
Removable boiler face
rear firebrick
1
3/16275
Removable boiler face
side firebrick
2
3/18172
Grate Baffle
1
Replacement parts if required are always available ex-
works. Write to us should any difficulty be encountered in
obtaining them from your usual supplier.
SMOKE/SMELL EMITTED DURING INITIAL USAGE
Some parts of the cooker have been coated with a light
covering of protective oil. During initial operation of the
cooker, this may cause smoke/smell to be emitted and is
normal and not a fault with the appliance, it is therefore
advisable to open doors and or windows to allow for
ventilation.
Lift the insulating lids to prevent staining the linings.
SPARES LIST
FUME EMISSION WARNING