To carry out servicing on the oil pump. Turn off the oil line
isolating valve near to the appliance.
SEE FIG. 10
1.
A container must be put under the pump to catch any
oil when starting to clean the oil pump strainer.
2.
Remove 4 socket head screws.
3.
Remove filter
4.
Wash with clean kerosene.
5.
Re-assemble in reverse order.
1.
Turn OFF the line isolating valve fitted prior to the oil
line filter.
2.
Follow manufacturers instructions to remove filter
element from the housing, taking care to collect
kerosene residue from the filter housing.
3.
Wash filter thoroughly in clean paraffin.
4.
Re-assemble in reverse order.
NOTE:
Flexible hose (s) must be replaced at each
service, ie. annually.