Raybend RCP110 Скачать руководство пользователя страница 8

Limited One Year Warranty

Limited One-Year Warranty

WHAT THIS WARRANTY COVERS:

When used and maintained in normal use and in accordance with 

the Owner’s Manual, your RAYBEND® product is warranted against 

original defects in material and workmanship for one year from the 

date of purchase (the “Warranty Period”). During the Warranty Period, 

RAYBEND® will repair or replace at no cost to you, to correct any 

such defect in products found upon examination by RAYBEND®, to be 

defective in materials or workmanship. 

WHAT THIS WARRANTY DOES NOT COVER:

Use of the product in a non-residential application, improper 

installation and/or maintenance of the product, damage due to 

misuse, acts of God, nature vandalism or other acts beyond control 

of RAYBEND®, owner’s acts or omissions, use outside the country 

in which the product was initially purchased and resale of the product 

by the original owner. This warranty does not cover pick up, delivery, 

transportation or house calls. However, if you mail your product 

to a RAYBEND® Sales and Service Center for warranty service, 

cost of shipping will be paid one way. This warranty does not apply 

to products purchased outside of the United States, including its 

territories and possessions, outside of U.S. Military Exchange and 

outside of Canada. This warranty does not cover products purchased 

from a party that is not an authorized retailer, dealer or distributor of 

RAYBEND® products. 

OTHER IMPORTANT TERMS:

This warranty is not transferable and may not be assigned. This 

Warranty shall be governed and construed under laws of the 

state of Michigan. The Warranty Period will not be extended by 

any replacement or repair performed under this Warranty. THIS 

WARRANTY IS THE EXCLUSIVE WARRANTY AND REMEDY 

PROVIDED BY RAYBEND®. ALL OTHER WARRANTIES, 

EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OR 

MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, 

ARE DISCLAIMED. IN NO EVENT WILL RAYBEND® BE LIABLE 

FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES OF ANY KIND OR NATURE TO OWNER OR ANY PARTY 

CLAIMING THROUGH OWNER WHETHER BASED IN CONTRACT, 

NEGLIGENCE, TORT, OR STRICT PRODUCTS LIABILITY OR ARISING 

FROM ANY CAUSE WHATSOEVER. Some states do not allow for the 

exclusion of consequential damages, so the above exclusion may not apply 

to you. This warranty gives you specific rights. You may also have other that 

vary from state to state.

© 2019 RAYBEND. All Rights Reserved.

2723 Kersten Court       Kalamazoo, Michigan 49048      269-254-8497

www.RAYBEND.com

61503-01

Содержание RCP110

Страница 1: ...IS PRODUCT Save these instructions for future reference Failure to read and follow the warnings and instructions within this instruction manual could result in property damage serious injury or death SPECIFICATIONS Power supply 115V 60 HZ 10 Amp Circuit Liquid Temp Range 32 F to 95 F 0 35 C Discharge 3 8 in Hose barb Model RCP110 Condensate Pump Use And Care Guide ...

Страница 2: ...5 volts single phase 60 Hz and is equipped with an approved 3 conductor cord and 3 prong grounded plug Do not remove the ground pin under any circumstances The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI ou...

Страница 3: ...NT Ensure the electrical power source is adequate for the requirements of the pump IMPORTANT Before using the pump check the tubing for holes or excess wear which could cause leaks and ensure the tubing is not kinked or making sharp angles Straight tubing allows the pump to move the greatest amount of water quickly and also check that all tubing connections are tight to minimize leaks IMPORTANT Th...

Страница 4: ...erfall pump Do not use where water recirculates Not designed for the drains of swimming pools NOTE This unit is non submersible The pump should not be installed in a manner that will subject it to flooding splashing or spraying Mounting the pump The tank has two slots 1 provided to mount the unit The slots are located on the back of the tank Mount the unit either on the side of the air conditioner...

Страница 5: ...of the pump intake port Cut the tubing at an angle so that the bottom of the reservoir does not close the tubing outlet Be sure the tubing does not interfere with the float INSTALLATION Continued Connect the Tubing Connect the tubing from the pump discharge hose barb to the floor drain laundry tub or sink Leave an air gap above the tub drain ...

Страница 6: ...rcuit to shut down the heating AC circuit The COM and NC switch contacts may be used to actuate a low voltage alarm circuit connected in series if the heating cooling system cannot be disrupted TESTING 1 Unplug the condensate pump so that it cannot pump out water Fill water into the pump reservoir until it is almost full The safety switch should activate before the float contacts the cover 2 Plug ...

Страница 7: ...ruction in dis charge tubing 6 Blocked check valve 1 Straighten the tubing 2 Shorten the discharge tubing 3 Clean any debris from reservoir 4 Measure the height from the pump to the highest point Rework discharge if greater than 18 5 Check line for blockage and remove any debris 6 Remove any debris around check valve Liquid is drain ing back into reservoir from discharge line 1 Damaged check valve...

Страница 8: ...hased outside of the United States including its territories and possessions outside of U S Military Exchange and outside of Canada This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of RAYBEND products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This Warranty shall be governed and construed unde...

Отзывы: