background image

 

2

The 

Ray Foster Cyclone Dust Collector

 was engineered for optimum suction at a low 

noise level, easy and economical filter changes, and minimal maintenance. 

 

It is designed for various grinding tasks in the dental laboratory, and is intended to 
be used in conjunction with bench lathes, high speed alloy grinders, micro motors, 
hand pieces, and other grinding tools. 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

To reduce the risk of fire, electrical shock, injury to persons or damage when 
using your Cyclone Dust Collector, follow basic safety precautions including 
the following: 

 

 

Read 

this manual before using your dust collector.

 

 

 

Ground the dust collector

. This unit is equipped with an approved three 

conductor cord and plug. It must be plugged into a three hole grounded 
receptacle. 

 

 

Disconnect

 the power cord before servicing or cleaning unit. 

 

 

Use with dry materials only.

 Do not use dust collector with any wet or moist 

material, such as gypsum models that have not thoroughly dried. Moisture will 
cause rapid wear of the motor, and the possibility of electrical short or electrical 
shock.

 

 

 

Do not

 operate unit without primary and secondary filters in place. 

 

 

 

Do not 

operate unit with a damaged or punctured filter bag.

 

 

 

Do not 

block the discharge vents. The dust collector discharges filtered air 

through vents on the right side of the unit. Allow at least four inches of clearance 
on this side for air discharge.

 

 

INSTALLATION 

 

1.  Choose a suitable location for the unit.  It is compact and portable and fits easily 

under a counter or bench. If you choose to place it inside a cabinet, be sure to 
provide adequate ventilation for the exhaust. The unit discharges air out the right 
side, DO NOT BLOCK this discharge in any way. 

 

2.  One 6 foot long by 2.5 inch diameter vacuum hose is supplied. Longer lengths 

are available if required. Also available is a 1.5 inch diameter vacuum hose for 
applications that require the smaller diameter hose. Insert one end of the hose 
into the open port on top of the dust collector, and the other end connects to the 
work station or dust collection devise. 

 

3.  Plug the unit into any standard GROUNDED electrical outlet. DO NOT 

circumvent the electrical grounding by removing the third prong. The dust 
collector is turned on (international symbol "I") and off (international symbol "O") 
by a rocker switch located on the front panel. The unit can also be controlled by 
an optional foot switch (P/N X131) or remote control box (P/N X145). 

 

Содержание CDC2

Страница 1: ...R Model CDC2 Operating and Maintenance Instructions Sales Service and Technical Assistance Call Toll Free 800 654 4519 Ray Foster Dental Equipment 5421 Commercial Drive Huntington Beach CA 92649 714 897 7795 Fax 714 898 6013 ...

Страница 2: ...secondary filters in place Do not operate unit with a damaged or punctured filter bag Do not block the discharge vents The dust collector discharges filtered air through vents on the right side of the unit Allow at least four inches of clearance on this side for air discharge INSTALLATION 1 Choose a suitable location for the unit It is compact and portable and fits easily under a counter or bench ...

Страница 3: ...TANT The disposable bag should be changed when there is a noticeable reduction in suction power Never empty and reuse the paper bag 2 Cloth Dust Bag item X112 The cloth dust bag is a semi permanent filter and requires removal and shaking periodically to prevent its pores from becoming clogged resulting in reduced suction CAUTION Never operate the dust collector with any filter missing or damaged a...

Страница 4: ...ssembly approximately two to three turns It is not necessary to remove the screws Lift the brush assemblies slightly and pull them out Insert the new brushes making sure the tab on the brass housing mates with the slot on the bracket Tighten the four Phillips head screws E Snap on the plastic fan cover and replace the bottom plate 4 Fuse item X166 The fuse is located on the back panel in the conne...

Страница 5: ...uld it become necessary to make repairs or replace any of the parts in the electrical system it is recommended that this diagram be consulted and observed in reconnection of electrical components and that color coding of existing wires be preserved Use only Foster approved replacement parts or their equivalent do not circumvent established electrical safeguards Disconnect unit from electrical outl...

Страница 6: ...r Cyclone Dust Collectors to be free of defects in material and workmanship for a period of one year from the date of purchase by the original user We do not guaranty that the motor brushes and filter bags will last one year as these are items that wear and must be replaced when needed To obtain warranty service the dust collector or defective part together with proof of date of purchase must be d...