![Ray Electric Outboards E2 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/ray-electric-outboards/e2/e2_repair-manual_789411013.webp)
13
TROUBLE SHOOTING CHART
Symptoms
Cause
Correction
1. Won't run.
Battery meter
Registers far left
"charge"
1. Batteries dead
2. Open at a battery
terminal
1. Charge or replace
batteries as necessary
2. Repair terminal
3. Key switch not
operating
3. Short across switch
terminals to verify.
Replace switch
4. Control cable
plug/socket unplugged
or damaged
4. Insert plug into
socket. Replace if
necessary
5. Anderson plug un-
plugged at motor
or damaged
5. Plug in plug.
Replace if necessary
2. Won't run.
1. PMC not operating
1. See "The PMC and
Battery meter
associated circuits"
registers "OK"
2. Green and orange
2. See "Shorts in control
wires shorted, causing
cable"
CF & CR to be on
simultaneously
3. Loose primary
3. Inspect and repair
terminal inside motor
cowl
4. Cp not operating
4. Check out Cp and
or has dirty contacts
red control circuit
See “Checking control
circuits”