5 ) System Message Descriptions
Displayed Message
Event Description
Remote/Pager Behavior
HIGH TEMP
ALERT!
The in-vehicle temperature
is at or above the Alert
Temp at
both
sensors.
Continuous,
alternating
vibrator and beeper (No
beeper if ‘MUTE’ is enabled).
VEHICLE POWER
ALERT!
The vehicle battery voltage
has dropped below
approximately 8 volts.
Continuous,
alternating
vibrator and beeper (No
beeper if ‘MUTE’ is enabled).
MOTION
ALERT!
The motion detector
(optional) has detected
motion inside the vehicle
while the system is powered
down
Continuous,
alternating
vibrator and beeper (No
beeper if ‘MUTE’ is enabled).
AUX INPUT
ALERT!
The auxiliary input has
received a pulse.
Continuous,
alternating
vibrator and beeper (No
beeper if ‘MUTE’ is enabled).
Table 5.1: Heat Alert Messages
Displayed Message
Event Description
Remote/Pager Behavior
LOW BATTERY
The Remote/Pager battery
needs to be recharged to
ensure continued operation.
Periodic vibration and beep
(No beeper if ‘MUTE’ is
enabled)
NO SIGNAL XX:XX
The Remote/Pager has not
received a signal from the
POD for the time specified
(approximate)
Vibration and beep after 2
minutes and every 10 minutes
after signal is lost (No beeper
if ‘MUTE’ is enabled)
Table 5.2: Remote / Pager Message
F3-G2 System Manual - Rev 7