6. Command Mode Commands 

6.1. General Command Common to Data Mode and Paging Mode 

These commands apply to the general configuration of the M8T, and are 
applicable in both the data modem mode and paging mode.   

Command

 

Command Description

 

Parameters

 

Factory

 

Default 

 

ATAT

 

Silence AFTER Sequence 

- Sets period of silence after the 

command sequence characters in mS.  

Range:0 – 1000 
(mS)  

500  

ATBD

 

Baud Rate 

– Sets serial com port baud rate (bps).  Type the 

range index (0-7) or the actual desired baud rate.  

Range: 0 – 7  
0 = 1200     5= 38400 
1 = 2400     6=57600 
2 = 4800     7=115200 
3 = 9600  
4 = 19200  

ATBT

 

Silence BEFORE Sequence 

– Sets period of silence before 

the command sequence character in mS.  

Range: 0-1000  
mS 

500  

ATCD 

Carrier Detect Threshold 

– Read/set the carrier detect 

threshold, in dBm.  -113 means  -113dBm.   

-113 

-120 to -60 

ATCH 

Configure Hardware Flow Control 

– Enable (1) or disable (0) 

flow control.  When enabled, the modem will monitor the RTS 
line, and if it is negated, stop sending data out the serial port.  If 
disabled, the modem will ignore the state of RTS, and always 
send out charators.  

  

1 = Enable 
0 = Disable 

ATCI 

Handshaking Invert 

– Used to invert the RTS handshaking 

signal. 0=normal, 1 = inverted. 

 

1 = Invert 
0 = Normal active low.  

ATCT

 

Command Time Out 

– If no valid commands have been 

received via the serial port within this time period (in 
milliseconds), modem returns to normal operation mode from 
Command mode.  If the CONFIG button inside the 

M8T 

is 

pressed, this parameter will be automatically set to 60000.   

Range: 100-60000mS  

60000  

AT

Echo –

 Character echo set on (E1) or off (E0).  This applies to 

the Command Mode only. 

 

Range: 0 , 1 

1 (echo) 

ATF 

Display frequencies 

– Display all of the frequencies 

programmed into all of the channel memories.

  

 

N/A 

ATFT 

Transmit Frequency – 

Program the transmit frequency for this 

channel. Enter in Hz or in MHz.  The frequency will 
automatically be saved in non-volatile memory (flash) for this 
current channel number.

 

Range: 

See product data 

sheet.  For MURS products, 
frequency cannot be 
changed.

 

See product 

data sheet. 

ATFR 

Receive Frequency – 

Program the receive frequency for this 

channel. Enter in Hz or MHz. The frequency will automatically 
be saved in non-volatile memory (flash) for this current channel 
number.

 

Range: 

See product data 

sheet.  For MURS products, 
frequency cannot be 
changed.

 

See product 

data sheet. 

ATFX 

TX and RX Frequency – 

Program the receive and transmit 

frequency for this channel. Enter in Hz or MHz. Same as 
issuing an ATFR and an ATFT command.  The frequency will 
automatically be saved in non-volatile memory (flash) for this 
current channel number.

 

Range: 

See product data 

sheet.

 

N/A 

AT

HN

 

Channel Number 

Select current radio channel number.  This 

command does not store the channel number into EEPROM,  

Range: 1 - 6  

1  

Содержание RV-M8T

Страница 1: ...y Confidential 1 Raveon Technologies Corp RV M8T RV M8R Data Paging Radio Modem Technical Manual Version A7 September 2013 Raveon Technologies Corporation 2461 Impala Drive Carlsbad CA 92010 www raveo...

Страница 2: ...Commands 14 6 1 General Command Common to Data Mode and Paging Mode 14 6 2 Data Modem Mode Related Commands 16 6 3 Paging Receiver Related Commands 18 6 4 Factory Default Settings 18 7 Using the M8T i...

Страница 3: ...on 36 11 2 Calibration Commands 36 11 3 Center Frequency 37 11 4 TX Deviation 37 11 5 TX Modulation Balance 37 11 6 RX Carrier Detect 38 12 Troubleshooting 40 Symptom Unit will not receive 40 Symptom...

Страница 4: ...g caps in a blasting area or in areas posted Turn off two way radio Obey all signs and instructions Potentially Explosive Atmospheres Turn off your radio prior to entering any area with a potentially...

Страница 5: ...nge or higher data throughput It is also available in a receive only version called the M8R The M8R is the same electrical design and has the same features as the M8T except the transmit circuits are...

Страница 6: ...er Features POCSAG decoder mode operates at 512 1200 and 2400 baud 1 3 programmable cap codes Promiscuous mode to receive all pages on the air Automatic and manual switching between numeric and alpha...

Страница 7: ...1K load 0 0 2V Digital Input High 3 0V Digital Input Low 0 3V Enable input High 1 40V DC Input 8 13V volts DC 3 2 Transmitter Specifications RV M8T xx RF Power Output 100mW 2 0 W programmable Maximum...

Страница 8: ...onnector Type 20 pin 2mm header DC Input 8 13V DC power draw RX mode 600mW DC power draw TX mode 2W 7W DC current draw standby mode 150uA IO Voltage Levels 3 3V digital logic RX and TX data Transparen...

Страница 9: ...e data output 7 Enable I Low 7V to shut down the module High 2 5V to enable it 8 Sleep i CPU Sleep input 9 CTS O Clear to send output Indicates state of internal buffers 10 RTS I RTS input for serial...

Страница 10: ...ycles up to 50 the module requires additional heat sinking If an external heat sink presses against the GND PAD are of the PCB the RF power transistor will run cooler and allow higher duty cycles 4 4...

Страница 11: ...e M8T modem from unintentionally entering the Command Mode because of the pattern occurring in a stream of data entering the modem there must be a pause in the data stream before the as well as a paus...

Страница 12: ...was 1234 the user would issue the following command ATDT cr and the modem will respond with 1234 CR LF OK CR LF To get on line help with a command enter the command and put a question mark in for the...

Страница 13: ...into the M8T modem once the Command Mode is exited 5 6 Exiting the Command Mode There are three ways to exit the command mode They are 1 ATCN Issuing the ATCN The M8T radio will exit the command mode...

Страница 14: ...mands have been received via the serial port within this time period in milliseconds modem returns to normal operation mode from Command mode If the CONFIG button inside the M8T is pressed this parame...

Страница 15: ...The time in milliseconds for the serial port to time out When data is entering the serial port and this amo0unt of time passes with no more data the M8T will begin to transmit the data over the air R...

Страница 16: ...tion 0 1 or 2 CHNUM Read number of channels This command will return the number of channels this product has 6 MODEL Read Model number Read the model number of the unit None M8T or M8R SHOW Show displ...

Страница 17: ...umber of bytes to send over the air in the pre amble Range 3 255 5 Varies based on data rate and radio type 7 typical ATRB Number of retries If this modem does not get an ACK back when it sends data t...

Страница 18: ...pager cap codes CC 1 12345 CC 2 1 CC 3 1 PM Promiscuous Mode Enable disable promiscuous mode 0 off 1 ON receive all paging messages 0 or 1 0 PR Pager Data Rate Parameter is 512 1200 or 2400 512 1200 2...

Страница 19: ...ATMA 3 POCSAG Channel number selected 1 WMX WMX 0 OFF Paging Settings Over the air paging baud rate 512 baud Alternate protocol pin 15 1 POCSAG 512 Paging data format DF Auto detect Paging Cap Code 1...

Страница 20: ...ta radio 3 POCSAG decode Pull input pin 15 high enabling the alternate protocol The factory default configuration is ATMA 3 and ATMT 0 7 1 Setting Cap Codes Cap Codes are the ID of the paging receiver...

Страница 21: ...word into bits 30 11 0 9 are encoded as ASCII 0 9 Values beyond 9 in each nibble i e 0xA through 0xF are encoded as follows 0xA Reserved possibly used for address extension 0xB Character U urgency 0x...

Страница 22: ...d the last codeword is filled with unprintable characters such as end of message end of text or null Null is the only character which can be incomplete The maximum length for a standard alpha numeric...

Страница 23: ...ow to send 8 bit binary data 2 End of Text DLE ETX 16 0x10 3 0x03 ETX end of the data frame 8 0 4 ASCII hex Checksum Optional Variable 0 FFFF The 16 bit checksum of all the previous bytes starting wit...

Страница 24: ...st user applications will seamlessly work using the M8T in its Packet Mode 6 Repeatable and Routable M8T packets are structured so that they may be repeated using a store and forward repeater and or r...

Страница 25: ...that from the factory all M8T modems are configured to simply work Plug in power and connect to the serial port at 9600 baud and the modems will communicate on the default channel Change the channel...

Страница 26: ...serial port data rate far in excess of the over the air rate the efficiency of the M8T in Packet Mode is approximately the same as other brand modems that cannot operate in a Packet Mode with the add...

Страница 27: ...numbering The Group Number is set with the ATGP xx command where xx is the group number ATGP 0 disables group numbering and is the default way the M8T radio modem works If the Group Number is set to a...

Страница 28: ...digit FF in the first two positions of the destination ID or in the last two positions of the destination ID will be interpreted as a broadcast and any modem with an ID that matches the two non FF di...

Страница 29: ...default configuration All units have address 1234 and all modems will talk to all other modems with address 1234 Example 2 a configuration that won t work Sending to Destination Address 1236 Receivin...

Страница 30: ...e radio can hear on the air REPEAT 0 disables store and forward repeating It is highly recommended that you use this method to configure your M8T as a repeater Important The Unit ID of the repeater mu...

Страница 31: ...iable to E D C and G To solve this problem some of the M8T modems are configured as repeaters The still are able to send and receive data but they also will repeat data out to the modems that are out...

Страница 32: ...Table may have up to 4 entries For example M8T B in the above example will have two entries in its Repeater Table The command to set the two entries is ATX1 1020 FFFF 1000 FFFF ARX2 1000 FFFF 1000 FF...

Страница 33: ...ud rate on the end stations to be fairly slow ATBD x Thus when they receive a poll request there is a delay as they send data in out of their serial ports and during this delay the repeater can do its...

Страница 34: ...channel 8 Transmit preamble 101010 pattern ML x Debug Message Level By default and at power on this level is set to 0 no debug messages 0 no debug or diagnostic messages 1 POCSAG and data reception r...

Страница 35: ...dio modem will respond with a list of certain operation statistics that it maintains All statistics start counting at 0 The ATST 1 command can be used to reset all statistics back to 0 except the run...

Страница 36: ...e only setting that may require adjustment is the center frequency After years of operation all crystals will age and change frequency slightly The ATR8 command is used to adjust the center frequency...

Страница 37: ...el 3 Read the frequency offset with the ATR8 command 4 Adjust the frequency to the center of the channel with the ATR8 command You can use the U key and the D key to change the settings up and down on...

Страница 38: ...f it is above this value Carrier Detect is asserted The pre set value may be change with the ATRA command Note Asserted means low Negated means high The CD pin will sit at about 3 3V when CD is not as...

Страница 39: ...cessary for the serial terminal to wake from sleep or enter an appropriate mode to receive data In this mode the Carrier Detect handshaking line is nominally low and only goes high to signal that data...

Страница 40: ...he M8 If the TX LED blinks the M8T is transmitting data Every time data enters the modem the TX LED should blink Solution 2 Verify that serial port timeout is OK The ATG0 command sets the number of mi...

Страница 41: ...s the issue Symptom Modem appears dead Solution 1 Verify the power is on When the modem has good DC power the PWR LED will blink once per second If it is not blinking either the modem does not have po...

Страница 42: ...Company Confidential 42 Raveon Technologies Corp 13 Mechanical A drawing is shown below...

Отзывы: