11 SERVICING

Energycatcher is a simple designed unit, no maintenance 
is required. The unit contains no mechanical, electrical or 
serviceable parts.
It is recommended that the Energycatcher should be 
subjected to a general condition and fl ue inspection with 
boiler maintenance by a competent person.
Ravenheat are a member of the Benchmark initiative and 
fully supports the aims of the programme, to improve the 
standards of installation and commissioning of central 
heating systems in the UK and to encourage in the 
regular servicing of all central heating system to ensure 
safety and effi ciency.

11.1

All routine boiler servicing requirements can be achieved 
by the removal of the Energycatcher front panel.
To remove  the boiler front panel see boiler manual.

For further information contact:

Ravenheat Ltd
Telephone:  0044(0) 113 252 7007
Fax: 0044(0) 113 238 0229
E-mail:         [email protected]
Website:       www.ravenheat.co.uk

Содержание Energycatcher

Страница 1: ...he present booklet are for guideline purposes only RAVENHEAT MANUFACTURING LTD CHARTISTS WAY MORLEY LEEDS LS27 9ET TEL 0044 0 113 252 7007 FAX 0044 0 113 238 0229 Website www ravenheat co uk E mail sa...

Страница 2: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 3: ...6677 3 Thank you for purchasing Energycatcher combiplus or combistore patented energy saving system which when used in conjunction with the arrangement listed below will save substantial amounts of e...

Страница 4: ...es of practice BS 5440 1 2000 Flues BS 5449 1990 Forced Circulation Hot Water System BS 5546 2000 Installation of Hot Water Supplies for Domestic Use BS 6700 1997 Design Installation Testing Maintenan...

Страница 5: ...TION ENERGYCATCHER FIXING WATER CONNECTIONS ENERGYCATCHER WITH REMOTE TANK STORE ENERGYCATCHER PIPEWORK SERVICING ALTERNATIVE ENERGYCATCHER SYSTEMS LIST OF SPARE PARTS PAGE 6 7 8 8 9 10 13 14 14 14 18...

Страница 6: ...catcher is attached to a condensing boiler thelowtemperatureofthisexhaustresultsinthepolluting gases condensing to the drain rather than going into the atmosphere 1 1 Summary savings using Energycatch...

Страница 7: ...Supplied By www heating spares co Tel 0161 620 6677 7 Section 2 GENERAL LAYOUT Fig 1...

Страница 8: ...or storage tank through the boiler combi type to the tap this preheated water is supplied totally free of charge it is cycled through the boiler where the higher than normal inlet temperature is sense...

Страница 9: ...t b 1 upper cross member and 1 lower T shaped cross member c 1 paper template d 1 polythene bag containing 2 22 mm flanged angle valves and fibre washers 1 15 mm angled valve blue and washer 1 angled...

Страница 10: ...t the frame if the wall is uneven 6 1 WHEN INSTALLING ENERGYCATCHER IT MUST BE FITTED IN CONJUNCTION WITH RAVENHEAT 120 150 CONDENSING BOILER THEREFORE ITS IMPORTANT TO FAMILIARISE YOURSELF WITH THE B...

Страница 11: ...olts and nuts into the upper studs of the secured backframe leave them slightly loose of the frame Fig 4 6 5 1 You may wish to run cold feed preheat pipes into the backframe It is best to use 15 mm pl...

Страница 12: ...the cold inlet later Note It may be necessary to slacken backrame from the wall to locate pipes in clips 6 6 Unpack and prepare the selected boiler for installation as set out in the main boiler manua...

Страница 13: ...for instance silikon spray Arexons or similar product 7 5 Taking Energycatcher lift it up on the top of the boiler while at the same time ensuring that the 2 flexible pipes condensing outlet pipe and...

Страница 14: ...not exceed 5 m total length Positioning of the tank must be above the Energycatcher or at the left or right hand side When fitting at the side use the hose which can be taken through the side of back...

Страница 15: ...Supplied By www heating spares co Tel 0161 620 6677 15 10 4 ENERGYCATCHER STAND ALONE UNIT Fig 11...

Страница 16: ...Supplied By www heating spares co Tel 0161 620 6677 16 10 5 WITH REMOTE STORAGE TANK Fig 12...

Страница 17: ...Supplied By www heating spares co Tel 0161 620 6677 17 Fig 13...

Страница 18: ...Benchmark initiative and fully supports the aims of the programme to improve the standards of installation and commissioning of central heating systems in the UK and to encourage in the regular servi...

Страница 19: ...e or provide DHW Energycatcher is a good investment to install in conjunction with solar panels and offers immediate returns There are other systems designs which are available 12 2 Increased energy s...

Страница 20: ...05 0 Flue extension 3 0010TUB12015 0 Flow pipe 4 0010TUB12005 0 Return pipe 5 0019ATT12005 0 Flue adapter 6 0014GUA11020 0 Flue gasket 7 0014RAC06005 0 Condensing trap 8 0013GUA01025 0 Gasket 24x15x2...

Страница 21: ...Supplied By www heating spares co Tel 0161 620 6677 21...

Страница 22: ...eserves the right to make changes and improvements in our products which may affect the accuracy of the information contained in thi leaflet Chartists Way Morley Leeds LS27 9ET Telephone 0044 0 113 25...

Отзывы: