USER’S GUIDE

         

         

CSI SYSTEM AAA (T) 780 SERIES

                             

                                     

WITH OR WITHOUT BUILT IN TIMER 

 

   

CONDENSING SYSTEM INNOVATION SUPER HIGH EFFICIENTY  AUTOMATIC MODULATING

             COMBINATION  BOILER FOR CENTRAL  HEATING AND DOMESTIC HOT WATER

    

  

1

It is the law that all gas appliances are installed by 
a competent person, in accordance with the gas 
safety installation and use current regulations.
To the current Gas Safety (Installation and Use)
Regulations B.S. 5440:2 - (2000).

All registered installers carry a I.D. card and 
have a registration number. Both should be re-
corded in your boiler log book. You can che-
ck 

your installer by the gas safe register

.

Escape of gas

Should a gas leak be suspected, contact your gas 
supplier without delay.
Do NOT search for space gas leaks with a naked 
fl ame.

WARNING: This appliance must be earthed.
Do not touch or tamper with this sealed unit or its 
components.

1  INTRODUCTION

1.1 Please carefully read the information in the
booklet to help you gain maximum if from your 
appliance with minimum trouble.

1.1.1 Your Ravenheat Condensing Combination 
Boiler has been designed to supply your Central 
Heating and Domestic Hot Water directly from one 
unit. When central Heating is operating, the 
circulation will be interrupted when domestic hot 
water is being drawn off. This will normally not 
affect the level of the heating.

1.2 CLEARANCES AROUND THE BOILER

Above 125mm     (5 inches)
Below 150mm     (6 inches)
Front   450mm     (18 inches)
Sides      5mm     (0.2 inches)
25mm (1 inch) at the front when installed
in a cupboard.

PLEASE NOTE

Due to the high effi ciency and resulting low fl ue  gas 
exhaust temperature a white plume of condensation
vapour (cool steam) will be emitted from the fl ue outlet
terminal, this is quite normal.  It will be particularly 
evident during periods of low outdoor temperatures or 
when the boiler is working at its optimum performance.

1.2.1 Minimum clearances are required for safety and 
maintenance.
Do not obstruct any purpose made ventilation opening 
if boiler has been fi tted in a compartment. Never hang 
clothes, etc., over the appliance.

1.3 USER CONTROLS

(See Fig. 1)

1.3.1 This appliance is designed to operate with the 
minimum of attention by the user.
All controls are to be found on the control panel.

1.4 OPERATING SAFETY CHECKS TO

PROTECT YOUR APPLIANCE

1.4.1 Before lighting the appliance check central
heating system pressure ( (7) is not less than 1 bar 
gauge. If it is below this do not light but consult your 
installer about refi lling your system as you may have a 
leak in the system.

1.4.2 A RED warning light on the control panel (8)
warns of a fl ame failure of the burner. This can be reset 
manually by pressing mains boiler on/off switch (1).

1.4.3 A RED warning intermittence light on the control 
panel (8) warns of a high temperature lockout on the 
overheat thermostat. This could occur due to air or poor 
circulation in the boiler/heating circuit. This can be reset 
manually by pressing mains boiler on/off switch (1). If 
lockout should persist leave the appliance shut down 
and consult your installer/service engineer
immediately.

1.4.4 The CSI SYSTEM AAA(T) 780 series condensing 
boiler is fi tted with a condensate outlet which must be 
connected by the installer to a suitable discharge point 
as specifi ed in the installation manual.
On no account should this discharge pipe be blocked 
or modifi ed.