13
Entering Boom Data.
1. Select desired boom number.
2. Enter boom length as detailed on page 8.
3. If a boom is not needed, enter a "0" for a length.
7) Enter SPEED CAL in key labelled:
8) Enter METER CAL calibration number in key labelled:
9) Enter FLOW RATE gal/acre [lit/ha] target application rate in key
labelled:
NOTE: A decimal point is displayed automatically. Therefore, twenty gallons per
acre is entered as 20.0, not 2.0.
YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE
The flashing "CAL" will now extinguish. If not, repeat procedure starting at
Step 6.
10)
To change VALVE CAL calibration number depress key labelled:
for 5 seconds. Display will flash. Enter VALVE CAL number. (See page 9 for default
VALVE CAL settings).
NOTE: To display operating mode (US, SI, TU), speed sensor type (SP1, SP2), and
valve control (C-Sd, C-FC) depress
for 5 seconds and continue holding.
2. OTHER DISPLAYS
1) To display TOTAL AREA covered, momentarily depress key labelled:
To "zero out" this total at any time, enter a "0" in this key.
2) To display TOTAL VOLUME sprayed, momentarily depress key labelled:
To "zero out" this total at any time, enter a "0" in this key.
3) To display DISTANCE (feet) [m] traveled, momentarily depress key labelled:
To "zero out" this total at any time, enter a "0" in this key.
4) To display MPH [km/h], momentarily depress key labelled:
3. SELF TEST FEATURE
SELF TEST allows speed simulation for testing the system while the vehicle
is not moving. Enter the simulated operating speed by depressing key
labelled: for 5 seconds (display will flash). If 6 MPH [9.6 km/
h] is desired, enter 6.0 [9.6]. (See CONSOLE PROGRAMMING on page 11).