Chapter 4
50
OmniSeed™ Viper Pro™ Installation & Operation Manual
12.
Weigh the product dispensed (minus the weight box) and enter the weight in the cal weight calibration
assistant.
13.
Touch the
Calculate
button. Viper Pro will calculate the cal weight value and enter the value on the Node
Settings screen.
14.
Toggle the product 1 switch off. To perform a catch test for additional product nodes or control channels,
toggle the appropriate product switch to manual and repeat the above process as necessary.
15.
Touch
OK
to save the entered value or proceed to the optional
section if applicable to continue
with the initial set up process.
Valve Cal(s)
Note:
The Viper Pro automatically enters the recommended valve cal value for the valve type selected
during the procedure in the Application and Control Valve Type(s) section on page 40.
1.
Touch within the
Product Control
area at the bottom of the main screen.
2.
Make sure that
Node 1
is selected on the CAN Controller Status screen and touch within the second data
display area, or the Product Control Settings area, on the CAN Controller Status screen.
3.
Touch the
Next
button to view additional settings for the selected product node or control channel.
4.
Touch the displayed valve cal value and use the keypad to enter the calibration value for the installed
control valve.
Note:
Raven recommends the following initial valve cal values:
These values are good starting points and will generally yield adequate results, however, the valve
cal should be refined for the individual control valves installed on the specific machine. Refer to
Appendix B, Calculating the Calibration Values, for more information on calculating the valve cal.
For ground drive carts use the standard valve cal as the initial valve cal value. For hydraulic drive carts,
enter the PWM close valve value as the initial value. These values are good starting points and will
generally yield adequate results, however, the valve cal should be refined for the individual control valves
installed on the specific machine. Refer to the
section on page 255 for more information about
adjusting the valve cal.
Note:
When operating a hydraulic drive system at extremely low seed application rates, the valve cal
may need to be adjusted to slow the PWM close valve and keep the seed rate from fluctuating at
these low rates.
5.
Repeat the above process for any remaining nodes or product control channels as necessary.
6.
Touch
OK
to save the entered value or proceed to the optional
section if applicable to
continue with the initial set up process.
Valve Type
Calibration Value
Standard Valve
2123
Fast or Fast Close Valve (C-F or C-FC)
743
PWM or PWM Close Valve (C-P or C-PC)
43
(Injection Pump) Motor Control Node
(select Standard Valve type)
123
Содержание OmniSeed Viper Pro
Страница 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Страница 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Страница 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Страница 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Страница 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Страница 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Страница 250: ...Appendix A 238 OmniSeed Viper Pro Installation Operation Manual FIGURE 1 OmniSeed System Diagram 3 Bin D N 054 5010 003 ...
Страница 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Страница 255: ...Manual No 016 3001 015 Rev C 243 FIGURE 6 Seed Blockage Sensor Cabling More than 60 Sensors D N 054 5002 002 ...
Страница 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Страница 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Страница 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Страница 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Страница 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Страница 307: ......