C
HAPTER
4
22
ISOBUS Product Control Installation & Operation Manual
TIERED BOOM SETTINGS
A tiered boom configuration has two or more booms stacked - one directly in front of the other - and may or may
not have different sets of nozzles capable of applying different rates.
NOTE:
Specialized plumbing, cabling, and a relay box are required to utilize a tiered boom configuration.
Generally, sprayers are not set up for this feature from the factory.
Refer to Tiered Boom Settings section on page 60 for more information on calculating the tiered boom settings.
SPINNER/FAN CONTROL SETUP
NOTE:
A meter cal value is required for either spinner speed control or monitoring spinner speed during
field operations. Refer to the following procedure to enter a meter cal on the Spinner/Fan Control
Setup screen for either spinner control or monitoring operations.
In a granular control system, the RPM of a fan or spinner may be monitored or controlled via the ISOBUS product
control system. To access the Spinner/Fan Control Setup screen from the Raven ISOBUS main screen:
1. Select the Tools Menu icon from the quick access softkeys.
2. Select the Product Control Calibration icon at the top of the screen.
3. Select the ‘Spinner/Fan Control Setup’ button. The Spinner/Fan Control Setup screen will be displayed.
Содержание ISOBUS Product Control
Страница 1: ...Copyright 2016 ISOBUS Product Control Installation Operation Manual 016 0171 362 Rev F 08 16 E28148 ...
Страница 6: ...Table of Contents iv ISOBUS Product Control Installation Operation Manual ...
Страница 10: ...CHAPTER 1 x ISOBUS Product Control Installation Operation Manual ...
Страница 14: ...CHAPTER 1 4 ISOBUS Product Control Installation Operation Manual ...
Страница 18: ...CHAPTER 2 8 ISOBUS Product Control Installation Operation Manual ...
Страница 56: ...CHAPTER 5 48 ISOBUS Product Control Installation Operation Manual ...
Страница 61: ...Manual No 016 0171 362 Rev F 51 FIGURE 3 ISOBUS Granular Product Control System 37 pin Product Cable ...
Страница 63: ...Manual No 016 0171 362 Rev F 53 FIGURE 5 ISOBUS Liquid Product Control System 22 pin Product Cable ...
Страница 65: ...Manual No 016 0171 362 Rev F 55 FIGURE 7 ISOBUS AccuFlow HP 3 Section Bar ...
Страница 66: ...APPENDIX 7 56 ISOBUS Product Control Installation Operation Manual FIGURE 8 ISOBUS AccuFlow 3 Section Bar ...
Страница 67: ...Manual No 016 0171 362 Rev F 57 FIGURE 9 ISOBUS AccuFlow HP 6 Section Bar ...
Страница 68: ...APPENDIX 7 58 ISOBUS Product Control Installation Operation Manual FIGURE 10 ISOBUS AccuFlow 6 Section Bar ...
Страница 78: ...APPENDIX 8 68 ISOBUS Product Control Installation Operation Manual ...
Страница 82: ...APPENDIX C 74 ISOBUS Product Control Installation Operation Manual ...
Страница 84: ...Index 76 ISOBUS Product Control Installation Operation Manual ...