background image

If the stove is in final cleaning mode, you must wait until it turns off.  

Unit is OFF, we can start. 

1- Press OK (main menu is displayed) 

2- Press button 2 to go to 2nd pictogram which is RDS setting 

3- An access code will be required, press button 2 until you reach code C2, and then press OK. 

It’s time to relax and talk with the customer, explain the maintenance that needs to be done on the 
stove and the reason of your visit today.   

In the meantime, the stove is lighting up, it is feeding pellets, the igniter is warming up, the combustion 
fan is turning on and flames appear.  MAGIC!  There is even a timer that appears in the RDS menu that 
tells you that in the next 9 minutes, the stove will be in start-up mode! 

Once in operation and the temperature has risen a bit, an audible signal (beep-beep) will tell you that 
you may now calibrate the stove.  At this time, the timer will give you 20 minutes to adjust the flame. 

The RDS menu will display 4 lines;   

1

st

 digit m/s 

 

 

 

 

 

2

nd

 digit g/min 

 

 

 

 

 

3rd digit smoke degree and timer 

 

 

 

 

 

4th digit auger status 

We want a nice pellet stove flame so the first line must be between 1,15 and 1,5 m/s. never below and 
not much higher than those values. 

To get there, by using buttons 1 or 2 you can play with the g/min values (the rmp at wich the 
combustion fan runs).  If the m/s is too high, reduce them with button 2 g/min.  If the m/s are too low 
(lower than 1,15), increase your g/min with button 1.  After having set your first line between 1,15 and 
1,50 m/s, you will have a stove with nice lively flames with pellets that move a bit in the bottom of the 
burner pot.   

You only have to wait that the 20 minutes are over and that the unit returns to the home screen which 
should display work mode or work modulation.   

Отзывы: