Use and maintenance manual Magnus
Pag.36
Rev.1 21/04/2021
COATING
Minimum (internal) dimensions of the coating
The cladding built around the chimney must comply with the following minimum internal measures:
Minimum measures
A
1550 mm
B*
700 mm
C
2000 mm
* distance from the front glass to
the rear wall
Dimensions of the front opening
D
1045 mm
E
515 mm
⚠
The dimensions described here are valid only for the use of the fireplace with the standard frame. If the other frames are
used, the dimensions of the coating are different and it is therefore necessary to consult the dedicated brochure.
Air vents
The cladding must be equipped with appropriate air intakes for internal ventilation. The air intakes must be placed in such a way
that they cannot be obstructed.
Minimum measures
X (inferior)
450 cm
2
Y (superior)
450 cm
2
Access door
The access door is required for
•
loading the pellets
•
annual maintenance
•
possible replacement of components
The access door to the chimney is recommended on both sides, or it can be provided only on the side where the electronics and
the door for loading the pellets are mounted, but all electrical components must be accessible.
Minimum measures
F
400 mm
G
1500 mm
A
B
C
D
E
X
Y
F
G
Содержание Magnus
Страница 1: ...USE AND MAINTENANCE MANUAL Magnus...
Страница 2: ......
Страница 26: ...Use and maintenance manual Magnus Pag 26 Rev 1 21 04 2021 Removing of the fixing brackets 1 2 3 x1 x2...
Страница 27: ...Use and maintenance manual Magnus Pag 27 Rev 1 21 04 2021 Assembly of the wheels x1 x1 1 2...
Страница 28: ...Use and maintenance manual Magnus Pag 28 Rev 1 21 04 2021 Assembly of the baffle 1 2 3 4...
Страница 71: ......