![Ravas ProLine Touch Basic Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/ravas/proline-touch-basic/proline-touch-basic_operation-manual_3815039041.webp)
Operation Manual RAVAS Proline Touch Basic
Rev. 6
41
Note: Data transmission and saving to file use the same structure of the data string.
Field
Max. length
Format
Terminal-No.
2
numeric
Date
8
Format depending on configuration
Time
5
Format HH:MM
Alibi-No.
4
numeric (number of record in data archive)
Gross weight
10
numeric (in divisions of scale calibration)
Net weight
10
numeric (in divisions of scale calibration)
Tare weight
10
numeric (in divisions of scale calibration)
Unit
2
Unit sign (kg or t)
Pieces
8
numeric
Note
: Only for operating mode 'Counting'
Reference weight (g)
9
numeric and always in g
Note
: Only for operating mode 'Counting'
Destination
24
alphanumeric
Recipe-No.
24
alphanumeric
Note
: Only for operating mode 'Recipe'
Product-No.
24
alphanumeric
Note
: For operating mode 'Gravity determination' this
field is used to transmit the package-No.
Target weight
7
numeric
Note
: Only for operating mode 'Recipe'
Net total
10
numeric
Note
: Updated after each weighing cvycle
Done
1
If the operator terminates the weighing cycle, the
character '*' is transmitted in the field 'Done', otherwise it
is left empty.
ID #1
24
alphanumeric
ID #2
24
alphanumeric
Note
: Contains the selected ID from the database
ID #3
24
alphanumeric
ID #4
24
alphanumeric
ID #5
24
alphanumeric