SERVICE
MANUAL
RAVAGLIOLI S.p.A.
RAVTD5040WD / 5060WD / 5080WD
RAVTD5080WS - RAVTD1760WS/1780WS
RAVTD1850WS - RAVTD2200WS
Code R0184 - rev.1.2
(01/2011)
Ravaglioli S.p.A. -
Via I° Maggio, n° 3 (Frazione di Pontecchio Marconi)
Page 9/22
40037 Sasso Marconi (Bologna - Italy)
Tel. 051/ 67.81.511 – Fax 051/ 84.64.67 e-mail: [email protected]
The console of the wheel aligner series WD communicates with the front measuring
heads directly through the cables provided; these must be connected to Serial Ports (or
standard RS232 serial to USB adaptors) and linked as later described. Front measuring
heads do not feature batteries and consequently these cables also provide power. The
charging of rear heads are done while the heads hare connected to the charging cables.
See Figure 12.
Attention: the + and – poles must be right, check this when put the heads on charging.
If the +/- poles are right the battery charge (green led on), if reversed it doesn’t charge.
Attention: never charge the battery with AC current (old model had AC current), with AC it seem the
battery is correctly charging (green led on), but after some hours it could be damaged.
Figure 12
“WD” SERIES