Spreading operation using the QUANTRON-K2 Control unit
71
5
5.2.2
Winter spreader with two actuators for the spreading width limiter
(Dispersion AUTO deactivated)
The option with 2 installed actuators enables switching from a symmetric to an
asymmetric spreading pattern while spreading.
1.
Select the desired function for spreading width limitation using the
L/R
key.
Select the side for the spreading width limiter plates that you wish to adjust
by pressing the
L/R
key multiple times.
Left
Right
Figure 5.4:
Asymmetric spreading pattern (example)
Spreading width adjustment to the road during spreading operation.
F1 [1]: Lower the spreading width limiter plates on the desired side.
F2 [2]: Raise the spreading width limiter plates on the desired side.
NOTICE
The position of the half-side slide must be adjusted to ensure even lateral
distribution.
NOTICE
More information on settings for the half-side slide is provided in the operating
manual for the AXEO winter spreader, chapter 7.7.
1
2
Содержание QUANTRON-K2
Страница 6: ...Table of Contents IV...
Страница 10: ...User notices 1 4...
Страница 26: ...Attachment and installation 3 20...
Страница 72: ...Operation QUANTRON K2 4 66...
Страница 90: ...Spreading operation using the QUANTRON K2 Control unit 5 84...
Страница 94: ...Alarm messages and possible causes 6 88...
Страница 96: ...Special equipment options 7 90...
Страница 100: ...Index D...
Страница 102: ......